Instructions prior to installation, Instructions prior to commissioning – DE DIETRICH MS 24 User Manual

Page 69

Advertising
background image

69

71.03982.03 - EN

OPERATING INSTRUCTIONS

This boiler has been designed to heat water to a temperature lower than boiling point at atmospheric pressure. It must
be connected to a central heating system and to a domestic hot water supply system according to its performance and
power output.
Before having the boiler installed by a qualified fitter, make sure the following operations are performed:
a) Make sure that the boiler is adjusted to use the type of gas delivered by the gas supply. To do this, check the markings

on the packaging and the rating plate on the appliance.

b) Make sure that the flue terminal draft is appropriate, that the terminal is not obstructed and that no exhaust gases

from other appliances are expelled through the same flue duct, unless the latter has been specially designed to collect
exhaust gas from more than one appliance, in compliance with current laws and regulations.

c) Make sure that, if the boiler is connected to existing flue ducts, these have been thoroughly cleaned as residual products

of combustion may detach from the walls during operation and obstruct the flow of fumes.

d) To ensure correct operation and maintain the warranty, observe the following precautions:

1. DHW circuit:
1.1.
If the water is harder than 20 °F (1 °F = 10 mg calcium carbonate per litre of water), install a polyphosphate

dispenser or an equivalent treatment system, compliant with current regulations.

1.2. Thoroughly flush the system after installation of the appliance and before use.
1.3. The materials used for the product’s DHW circuit comply with Directive 98/83/CE.

2. Heating circuit
2.1. new system

Before proceeding with installation of the boiler, the system must be cleaned and flushed to eliminate residual
thread-cutting swarf, solder and any solvents, using suitable proprietary products. To avoid damaging metal, plastic
and rubber parts, only use neutral cleaners, i.e. non-acid and non alkaline. Recommended cleaning products are:

SENTINEL X300 or X400 and FERNOX Regenerator for heating circuits. Use these products in strict compliance
with the manufacturers’ instructions.

2.2. existing system:

Before installing the boiler, drain the system and clean it to remove sludge and contaminants, using suitable
proprietary products as described in section 2.1.

To avoid damaging metal, plastic and rubber parts, use only neutral cleaners, i.e. non-acid and non-alkaline such as

SENTINEL X100 and FERNOX Protector for heating circuits. Use these products in strict compliance with the
manufacturers’ instructions.

Remember that the presence of foreign bodies in the heating system can adversely affect boiler operation (e.g.

overheating and excessive noise of the heat exchanger).

Failure to observe the above will render the warranty null and void.

1. INSTRUCTIONS PRIOR TO INSTALLATION

Initial lighting of the boiler must be carried out by an authorised Service Engineer who must first ensure that:
a) the rated data correspond to the supply (electricity, water and gas) data;
b) the installation complies with current laws and regulations;
c) the appliance is correctly connected to the power supply and earthed. Failure to observe the above will render the

guarantee null and void.

Prior to commissioning, remove the protective plastic coating from the boiler. Do not use any tools or abrasive detergents
to do this as you may damage the painted surfaces.

The appliance is not intended to be used by persons (including children) with reduced physical, sensory or mental

capacities, or who lack experience or knowledge, unless, through the mediation of a person responsible for their

safety, they have had the benefit of supervision or of instructions on the use of the appliance.

2. INSTRUCTIONS PRIOR TO COMMISSIONING

Advertising
This manual is related to the following products: