Technician Troubleshooting Guide

Model 481BA (D-20)

2

3

Intracom D-20

VOLUME

OFF ON

SP-205A

9

8

7

6

5

4

1

2

3

Figure 1. Operating Controls

Key

Control Name

Function

1

Power Switch

Provides power to mainstation.

2

Power Indicator Light

Indicates power is on and the system is ready to operate.

3

Volume Control

Adjusts INCOMING audio level.

NOTE: Volume level adjustments for alert tone and outside
speakers are set by the installer.

4

Channel Selector Switches (1-6)

These switches control talk/listen communication for
numbered channels. Operator touches switch to talk and
releases switch to listen.

5

Indicator Lights

Red indicates TALK mode.
Green indicates LISTEN mode.
Yellow (steady) indicates channel on "HOLD."
Yellow (flashing) indicates incoming call WAITING.

6

Hold Switch

Places selected channel in "HOLD" mode.

7

All Call Switch

Controls conversation with all channels simultaneously.

8

Standby Switch

Silences incoming audio to eliminate undesired background
noise pickup when unit is not in use. Touching any
CHANNEL SELECTOR SWITCH releases STANDBY
mode.

9

Standby Indicator Light

Indicates unit is in STANDBY mode.

Advertising