Unpacking Procedure

Follow this procedure to unpack a SwitchModule:

1 Verify that the SwitchModule is the model that you

ordered by examining the model number on the side of
the shipping carton.

2 Remove the SwitchModule, in its antistatic bag, from

the shipping carton.

3 Following the instructions in Section 5.0, "Installation

Precautions", remove the SwitchModule from the
antistatic bag and inspect it for damage.

If the SwitchModule appears to be damaged, return it
to the antistatic bag, repack it in the shipping carton,
and contact your local supplier.

Keep the shipping carton and antistatic bag in which
your SwitchModule was shipped for future storage or
shipment.

4 Record the serial number of your SwitchModule. Use

the CoreBuilder 5000 SwitchModule Planning Chart
that comes with this product.

5 Ensure that the CoreBuilder 5000 SwitchModule Kit

contains these items:

CoreBuilder 5000 SwitchModule

Release Note for CoreBuilder 5000 SwitchModules

3Com DocsOnCD documentation CD-ROM (contains
CoreBuilder 5000 SwitchModule User Guide)

CoreBuilder 5000 SwitchModule Quick Start and
Reference
(this guide)

CoreBuilder 5000 SwitchModule Command Reference

CoreBuilder 5000 SwitchModule Planning Chart

CLASS 1

LED PRODUCT

7.0

Installing the SwitchModule

You do not need to turn off the CoreBuilder 5000 hub to
install

or

remove

the SwitchModule. You can install the

SwitchModule while the hub is operating (which is called a
hot swap).

Before you start the installation process, read
Section 3.3, "Software Prerequisites,
" and Section
5.0, "Installation Precautions"
.

To install a SwitchModule:

1 Determine hub power. To ensure that the hub has

enough power to support the new SwitchModule:

a Enter the SHOW POWER BUDGET command to see if

sufficient wattage is available from the +5 volt,
–5 volt, and +12 volt supplies.

b Using the values in the following table, add up the

total power requirements for the SwitchModules that
you plan to install:

Power Requirement at

Model Number

+5 Volts

–5 Volts

+12 Volts

3C96618M-TX-A

52 W

0.5 W

0.25 Watts
for all
modules

3c96620M-TP-A

25 W

0.5 W

3C96612M-TP-A

23 W

0.5 W

3C96624M-TP-A

30 W

0.5 W

3C96624M-TPL-A

25 W

0.5 W

3C96616M-BTP-A

35 W

1.0 W

3C96610M-F-A

33 W

0.5 W

3C96620M-F-A

50 W

0.5 W

3C96614M-FTP-A

30 W

0.5 W

3C96612M-FF-A

40 W

0.5 W

3C96604M-F-A

31 W

0.5 W

3C96612M-FC-A

57 W

0.5 W

3C96604M-TX-A

34 W

0.5 W

3C96604M-FX-A

35 W

0.5 W

Advertising