Dampertech_2010 178, Fsaf24-bal(-s) us, Caution equipment damage – Belimo FSAF24 User Manual

Page 8: Warning live electrical components! g

Advertising
background image

800-543-9038 USA

866-805-7089 CANADA

203-791-8396 LATIN AMERICA

178

FSAF24-BAL(-S) US

Spring Return, 24 V, 3-Position, 100% Open Override

Operation at 250°F for limited time per UL555S testing

Accessories (AF series accessories may be employed)

IND-AF2

Damper position indicator

K4-1 US

Universal clamp for up to 1.05” dia. jackshafts

KH-AF

Crank arm for up to 3/4” round shaft (Series 2)

KH-AF-1

Crank arm for up to 1.05” jackshaft (Series 2)

KH-AFV

V-bolt kit for KH-AF and KH-AF-1

Tool-01

10 mm wrench

ZDB-AF2

Angle of rotation limiter

ZG-100

Universal mounting bracket

ZG-101

Universal mounting bracket

ZG-103

Universal mounting bracket

ZG-104

Universal mounting bracket

ZG-106

Mounting bracket for Honeywell

®

Mod IV replacement or new

crank arm type installations

ZG-107

Mounting bracket for Honeywell

®

Mod III or Johnson

®

Series

100 replacement or new crank arm type installations

ZG-108

Mounting bracket for Barber Colman

®

MA 3../4.., Honeywell

®

Mod III or IV or Johnson

®

Series 100 replacement or new

crank arm type installations

ZG-AF

Crank arm adaptor kit for AF/NF

ZG-AF108

Crank arm adaptor kit for AF/NF

ZS-100

Weather shield (metal)

ZS-150

Weather shield (polycarbonate)

ZS-300

NEMA 4X housing

22965-00001

12 mm form fit square shaft adaptor

For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo
Mounting Methods Guide.

NOTE: When using FSAF24-BAL(-S) US actuators, only use accessories listed on this page.

Typical Specification

Where indicated on drawings, combination fi re and smoke and balancing dampers
shall be controlled by Belimo FSAF24-BAL or equal actuators. The actuators must
be designed so that they may be used for either clockwise or counter clockwise
failsafe operation. Actuator shall open damper in <75 seconds per UL555S and shall
spring closed in under 20 seconds. Actuators shall have a 5-year warranty and be
manufactured under ISO9001 International Quality Control Standards.

Actuator shall have an adjustable Maximum Opening Potentiometer which shall be
used by the TAB contractor to adjust fl ow to that portion of the system fed by the
damper.

The actuator shall spring closed if either the smoke detector or alarm system
removes power from it. Actuator shall spring closed if the primary temperature
thermodisc opens due to high ambient of >165°F or as otherwise indicted on
drawings.

The actuator shall drive full open if either the smoke control system 100% open
override or Fire Fighters Smoke Control Station override is activated. Damper shall
spring closed again if the thermodisc of a combination fi re and smoke damper opens
due to high temperature (typically 250°F).

Wiring Diagrams

1

Provide overload protection and disconnect as required.

2

CAUTION Equipment Damage!

Actuators may be connected in parallel.
Power consumption and input impedance must be observed.

3

Actuator may also be powered by 24 VDC.

4

Only connect Hot, Wire 2 to Wire 3 override control

5

For end position, interlock control, fan start-up, etc., FSAF24-BAL-S
incorporates two built-in auxiliary switches: 2 x SPDT, 7A resistive, 2.5A
inductive 120/250 VAC, UL listed, one switch is fi xed at 10°, one adjustable
30° to 90°

6

For end position indication, interlock control, fan startup, etc.,
FSAF24-SR-S US incorporates two built-in auxiliary switches:
2 x SPDT, 7A resistive, 2.5A inductive 120/250 VAC, UL Approved, one
switch is fi xed at 10°, one is adjustable 30° to 90°.

6

Meets UL requirements without the need of an electrical ground
connection.

7

Double insulated

WARNING Live Electrical Components!

G

During installation, testing, servicing and troubleshooting of this product, it may be

necessary to work with live electrical components. Have a qualifi ed licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
tasks. Failure to follow all electrical safety precautions when exposed to live electrical compo-
nents could result in death or serious injury.

1

24 VAC Transformer

Line

Volts

4

OVERRIDE CONTROL
See Wiring Diagrams
on following pages for
typical methods.

3

1 Blk Com
2 Red Hot

3 Override Open

FSAF24-BAL US

2

6

7

0793-00001_p

g

2

Override control

S1

S2

S3

S4

S5

S6

5

2

NC

NO

NC

NO

10°

30° to 90°

FSAF24-BAL-S US

7

70793-00001_p

g

2

Auxiliary switch

M40024 - 05

/10 -

S

ubject to change.

©

Belimo

Aircontrols (U

S

A),

Inc.

Advertising
This manual is related to the following products: