Tannoy V300 User Manual

Page 16

Advertising
background image

13.3 Biamp System Parameters



Parameter

Unit/Name

Low Section

High Section


Gain

(dB)

0

-6

Delay

(ms)

0

0

Polarity

Positive

Positive


HPF

â

Freq (Hz)

45.1

1920

Slope (dB/oct)

24

24

Filter Shape

Butterworth

Linkwitz Riley

LPF

Freq (Hz)

1820

Thru

Slope (dB/oct)

24

NA

Filter Shape

Linkwitz Riley

NA


Freq (Hz)

60.1

6100

Level (dB)

+7

+3.5

Type

Parametric

Hi - Shelf

PEQ 1

в

в

Q / Bandwidth

2.8 / 0.3536

NA

Freq (Hz)

281

10500

Level (dB)

-2.5

+4

Type

Parametric

Parametric

PEQ 2

Q / Bandwidth

2 / 0.500

9.5 / 0.1051

Freq (Hz)

749

NA

Level (dB)

-2

NA

Type

Parametric

NA

PEQ 3

Q / Bandwidth

2 / 0.500

NA

Freq (Hz)

606

NA

Level (dB)

-2

NA

Type

Parametric

NA

PEQ 4

Q / Bandwidth

6 / 1.669

NA

Freq (Hz)

1650

NA

Level (dB)

-2

NA

Type

Parametric

NA

PEQ 5

Q / Bandwidth

7.1 / 0.1403

NA


в

в

Note : When using the V300 with subs, set HPF on LF section @ 80 – 100Hz

(24dB/oct LR) and omit PEQ1 (on LF only)

PEQ 1 (on LF only) may also be omitted when using the V300 as a floor monitor.

Advertising