1 cleaning the air filter, 2 message table – 3M MP8640 User Manual

Page 23

Advertising
background image

© 3M 1997

3M

Multimedia Projector MP8640

Section 6: Maintenance

6.1 Cleaning the Air Filter

Note:

Clean the air filter about every 50 hours.

a) Turn off the MAIN POWER switch of the projector and pull out power cord. Let cool for 20 minutes.

b) Remove the air filter from the bottom of projector. Unscrew two retaining screws and pull down and

out on the handle to free air cleaner door. Carefully lift up and out on filter door.

ON indicator

LAMP indicator

TEMP indicator

Indicator status

Lights orange

Blinks green

Lights green

Blinks orange

Lights red

Blinks red

Lights red

Blinks red

Meaning

Standby mode

During warming up

During operation

During cooling down

Lamp cannot light

Air filter open

Temperature inside too high

Cooling fan not operating

Remedy

normal

normal

normal

normal

Cool projector by power off for 20 minutes.

Ensure filter is closed.

Let projector cool 20 minutes. Check air flow and filter.

call your dealer

6.2 Message Table

a) On Screen Display. The following messages are displayed on the screen:

NO SIGNAL IS DETECTED:

The projector is not detecting a signal.

SYNC IS OUT OF RANGE:

The horizontal frequency of the input signal exceeds the range
of the projector, or it cannot be displayed.

CHANGE THE LAMP:

Change when the lamp message appears on the screen. See
Section 6.3 for more information.

b) Indicator Display. The ON indicator, LAMP indicator and TEMP indicator will light or blink in the

following cases:

*When the LAMP indicator lights or blinks, turn the power off. If the problem persists, contact your dealer.

23

c) Clean the air filter using a vacuum cleaner. If dirt is still present, wipe the air filter with a cloth

moistened with water and wipe with a dry lint-free cloth.

d) After filter dries completely, re-install the air filter.

Note:

If air flow is restricted due to dust accumulation on filter, the projector may shut down due to over heating.

Remove the air filter

Advertising