20

Connecting Hubs Using 10BASE-2

Connect a 10BASE-2 ‘Y’ piece to each of your hubs
(Hub 8C only). Connect the ‘Y’ pieces with 10BASE-2 cable
to form a single segment, as shown in Figure 7. Remember
to terminate the two free ends of the segment by fitting
terminators (end pieces).

To disconnect a 10BASE-2 cable, twist each connector
counter-clockwise to unlock it, and remove it.

When using 10BASE-2 cable, it is important that both
ends of the segment are properly terminated with
50 Ohm terminators (end pieces).

Only use 50 Ohm 10BASE-2 cables and a ‘Y’ piece for
each hub. You can use ‘T’ pieces but ‘Y’ pieces
provide optimum clearance of the other ports.

Checking Connections

When you have connected your hubs, power them on.
The Port Status LEDs for the 10BASE-2 ports you have used
should be off. If they are not, check your connections.

Figure 7 Correct Hub Connections Using 10BASE-2

50 Ohm

terminator

10BASE-2 50 Ohm cable.

Minimum length of

each cable is 0.5m (1.6ft)

Maximum segment length is 185m (607ft)

(from terminator to terminator)

‘Y’ piece

50 Ohm

terminator