3M™ MicroTouch™ Controller SX112 Reference Guide

27

3M Touch Systems, Inc. Proprietary Information

Table 12 SX112 Serial Controller Factory Default Settings

Operating Parameter

Default

Baud Rate

9600

Serial Communication Settings

N, 8, 1

Data Format

Format Tablet

Operating Mode

Mode Stream

Return to Factory Calibration

Yes

The Restore Defaults command requires approximately 1.8 seconds. Therefore, the
application program should wait the maximum amount of time and be sure it receives the
command response before issuing another command to the controller.

Note

: After you issue a Restore Defaults command, you must recalibrate your sensor

using a 2-point calibration.

Response:

<SOH>0<CR> Positive response.

Unit Type

Syntax:

<SOH>UT<CR>

Description:

Responds with an 8-character identity string. This string identifies the type of controller
currently attached to the system, lists the features supported by the controller, and outputs
the status of the controller hardware (a self-test code).

Response:

Returns an identification code up to 8 ASCII characters in the following format:
<SOH>TtFfffSs<CR>

where:

Tt

= Two ASCII characters that identify the controller type.

TP = pen controller

Ffff

= Four ASCII characters that indicate the features supported by the controller.

**** = Indicates no additional features configured

Ss

= Two ASCII characters that provide status information about the controller

hardware. The two characters represent one byte. Each character is in the range
0 to 9 and A to F.
Table 2 defines the meaning of each bit (LED minus 1) in the status byte. Each
bit can be set to 1 or 0, where:
1 =

Error

0 = No error
00 = No diagnostic errors (normal response)