5.8.5. Setting the sample rate
The sample rate controls how often the depth, time, tank pressure, and water temperature
is stored in the memory.
You can set the dive profile sample rate to 1, 10, 20, 30, or 60 seconds. The factory default
setting is 20 seconds.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.6. Setting the Safety Stops/Deep Stops
The Deep Stop setting allows you to view Deep Stops. If Deep Stops are set to OFF, only
the traditional Safety Stop calculation is used.
If set to ON, iterative Deep Stops will be prompted as well. The length of the individual
Deep Stops can be set to 1 or 2 minutes.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.7. Setting the RGBM values
For certain divers and diving conditions, it may be desirable to set the attenuated RGBM
mode. The selection is displayed during the DIVE mode startup. The options are full RGBM
effects (100%), and attenuated RGBM (50%).

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.8. Setting the units
Use Unit Settings to choose between metric (meters/celsius/bar) and imperial
(feet/fahrenheit/psi) units.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.9. Setting the tank pressure alarm
The tank pressure alarm can be set "ON" or "OFF" and in the range of 10 - 200 bar. The
alarm is the secondary cylinder pressure alarm point. The alarm is activated when the
tank pressure drops below the set limit. The 50 bar alarm, however, is fixed and cannot
be changed.