background image

Ridge Tool Company

5

K-39, K-39B, K-40

Cleaning Drain Line

1. Insert cable into drain opening by hand as far as possible before turning

machine on. Leave approximately 6” of cable between drain opening and

nose of machine (Figure 5).

Figure 5 – Keep Distance Between Drain Opening and Nose of Drain

Gun to 6” or Less
2. Be sure machine FORWARD/REVERSE button is in the FORWARD

position.

3. Squeeze trigger and be sure entire cable is spinning before continuing.

NOTE! The K-39 autofeed cannot be used while the hand grip chucking

mechanism is engaged. Be sure the hand grip is pushed forward all the way.

4. Depress the forward autofeed lever to feed cable into drain.

NOTE! Know how long your run of pipe is prior to cleaning. Running too much

cable can damage your equipment and the cable.

5. Feed cable into drain until obstruction is encountered or cable begins to

bind up.

6. K-39: Release the forward autofeed lever and back the cable up using

the reverse autofeed lever. Then use the forward lever to again feed the

cable to remove the obstruction a piece at a time. Continue this back and

forth until you have broken through the obstruction.

K-40: reverse the machine direction to retrieve the cable. Then reverse

again to forward the cable. Repeat till you have broken through the

obstruction.

WARNING: Do not allow tension to build up in the cable. This will happen if

the cutting tool hits a snag and stops turning but the motor and cable continue

to rotate. Torque builds until the cable suddenly twists, potentially wrapping

around your hand or arm. This can happen quickly and without warning, so

proceed slowly and carefully as you feed the cable into the drain. If tool gets

hung up in an obstruction, refer to Reverse Operating Instructions in the

“Special Procedures” section.

7. Once drain is open and fl owing, continue feeding additional cable with

autofeed to clean rest of drain.

8. To retrieve cable, simply depress the reverse autofeed lever (K-39) or pull

the cable back by hand (K-40).

NOTE! K-39: There is no need to reverse the motor direction to retrieve the

cable. Simply depress the reverse autofeed lever.

9. Completely release trigger just prior to cable or tool emerging from drain

opening. Retrieve by hand as cable or tool may contain debris and splash

work area.

Special Procedures

Reverse Operation

If cable/blade gets hung up in obstruction, release trigger switch and let motor

come to a complete stop before reversing.

Place FORWARD/REVERSE button in REVERSE position. Press trigger

switch only until cable/blade is free of obstruction. Release trigger switch

immediately.

CAUTION: Only run machine in REVERSE if relieving blade from a

blockage.

NOTE! When motor direction is in reverse; autofeed directional levers will be

reversed, (FORWARD will become REVERSE and vise versa).

As soon as cable/blade is free and motor has stopped, return FORWARD/

REVERSE button to FORWARD position.

Loading Cable Into Cable Canister

WARNING: Make sure machine is unplugged from power source before

loading cable.

Your K-39, K-39B and K-40 is supplied with an inner drum that fi ts snugly

inside the cable canister that allows easy change-out of cable. K-39 Models

that include extra cable as standard equipment come with an inner drum for

each cable. To utilize the inner drum feature:

1. Pull hand grip forward to the disengaged position.

2. Loosen the four (4) screws that hold the canister front half to the back

half. Loosen each screw 3 (three) full turns (Figure 6).

3. Separate the canister front half from the back half by twisting apart.

4. Lift the inner drum, with cable, out of its cradled fi t.

5. Fit the new inner drum into the canister’s back half and draw about a foot

of cable out of the inner drum (Figure 7).

Figure 6 – Loosen Four (4) Screws From Back Half of Canister About

Three (3) Full Turns