Maintenance – Skil 0520 AA User Manual

Page 6

Advertising
background image

- use a target surface of at least 3 x 3 m, when

measuring long distances (12 - 15 m)

- ensure that no other ultrasonic sources are in the

vicinity

- when measuring through door en window openings,

ensure a correct result by measuring from two or
three different positions and compare the results

- the ultrasonic waves do not penetrate glass/windows
- in case of severe temperature changes, allow the tool

to adjust to the ambient temperature for half an hour
before starting new measurements

- fluctuations in air pressure and humidity, wind noise

and other sources of noise may lead to faulty
measurements

Single measurement

8

- press button F

3

- aim the tool towards the target surface
- press "Read" button; measurement appears on top

line of display

- measurement is repeated continuously until "Read"

button is released (ticking sound)

- each new single measurement erases the previous

one

Multiple measurement

9

- press button H

3

- aim the tool towards the first target surface
- press "Read" button; first measurement appears on

top line of display

- aim the tool towards the second target surface
- press "Read" button; second measurement appears

on top line of display (small figure 2 appears in upper
right corner of display and sum of two measurements
appears on bottom line of display)

- in the multiple measuring mode a maximum of

10 measurements can be added

- the small figure in upper right corner of display

indicates the measurement number (1 - 10)

- press button H

3

again for starting a completely new

multiple measurement

Surface measurement

0

- press button G

3

once

- aim the tool towards the first target surface (length)
- press "Read" button; measured length appears on top

line of display

- aim the tool towards the second target surface

(width)

- press "Read" button again; measured width appears

on top line of display while calculated surface
appears on bottom line of display

- press button G

3

twice for starting a completely new

surface measurement

Volume measurement

!

- press button G

3

twice

- aim the tool towards the first target surface (length)
- press "Read" button; measured length appears on top

line of display

- aim the tool towards the second target surface

(width)

- press "Read" button again; measured width appears

on top line of display while calculated surface
appears on bottom line of display

- aim the tool towards the third target surface (height)
- press "Read" button again; measured height appears

on top line of display while calculated volume appears
on bottom line of display

- press button G

3

twice for starting a completely new

volume measurement

Recall of previous measurements
Press "Recall" button for reviewing previous
measurements, starting with the last measured distance
(10 at the maximum)

Correction of multiple measurement
- press "Recall" button; last measurement and

corresponding small figure starts to blink

- press "Recall" more often until measurement to be

corrected is found

- press "Clear" button; measurement is replaced by 0

and sum of remaining values appears on bottom line
of display

- aim the tool towards target surface for new

measurement

- press "Read" button; new measurement replaces 0

and new value is added to the sum

- for continuing multiple measurement, press "Read"

button again and small figure jumps to next empty
memory place

- corrections are possible for 10 previous

measurements at the maximum

Correction of surface/volume measurement
- press "Recall" button; last measurement and

corresponding line of length/width/height starts to
blink

- press "Recall" more often until measurement to be

corrected is found

- press "Clear" button; measurement is replaced by 0

and recalculated value appears on bottom line of
display

- aim the tool towards target surface for new

measurement

- press "Read" button; new measurement replaces 0

and value on bottom line of display is recalculated
again

- press "Read" button again for continuing

surface/volume measurement

Faulty measurement
- when the measurement is unsuccessful, symbol

@

appears on display

- press "Read" button or restart the tool

Belt bag for easy and convenient storage

#

MAINTENANCE

Do not expose the tool to continuous vibration or
extremely hot or cold temperatures

Always store the tool indoors in its protective
carton/case

Always keep the tool free of dust, moisture and direct
sunlight

6

SKIL_IB0520v2 07-01-2009 14:34 Pagina 6

Advertising