Or 1. operating instructions, P2 p 2 s 1 s 1, Factory settings – STIEBEL ELTRON RTF Z 24.06.2003 - 19.12.2004 User Manual

Page 5: 1 first start-up, 2 setting the time and day of the week, Displays

Advertising
background image

5

Deutsch

English

M

+

OK

6

9

3

15

21

S1

Mo - Fr

Sa - Su

S1

E1

E1

S2

S3

E2

E3

E1

E2

S1

S2

P1

P2

P3

12

18

24

time

comfort temperature

otherwise

Off-peak temperature

pr

ograms

6

00

6

00

12

00

9

00

9

00

14

00

16

00

17

00

23

00

23

00

7

00

23

00

1 2 3 4 5

6

6

12

18

24

0

7

P

2

P

2

S

1

S

1

P

2.5

or

1. Operating instructions

for the user and the qualified installer

The RTF-Z with digital weekly timer serves
for individual control of the heat emission of
floor heating units. For this, a choice can be
made between four operating modes (timer
program, comfort temperature, off-peak
temperature, and frost protection).

After connecting to the mains supply until
setting the time, the thermostat automatically
switches to the „comfort temperature“
operating mode, and regulates the floor
heating unit to the temperature value set at
the factory. After setting the clock, the
thermostat then switches to the „timer pro-

gram“ operating mode.

Heating up of the floor heating unit is identified
by the function symbol „heating operation“.

It is possible to switch off the heating operation
by changing to the „Frost protection

!

operating mode.

1

Mode - select an operating mode or
function by repeated pressing

2

Reset - restore the factory setting.
Briefly depress the flush-fitting push-
button with a non-conductive blunt object.

3

Increase the set value

4

Decrease the set value

5

Confirm the set value

6 Display

1

2

3

4

5

6

8966.01

8967.01

Functions

Heating operating
Time

P

Program selection

Timer programs
P1 Program 1
P2 Program 2
P3 Program 3

Operating modes
!

Frost protection
Off-peak temperature
Comfort temperaure
Timer program

Days of the week
1-5 Monday - Friday
6+7 Saturday + Sunday

Start / end time in the timer program
S1 1st start time

E1 1st end time

S2 2nd start time

E2 2nd end time

S3 3rd start time

E3 3rd end time

Value indicator
Setpoint floor temperature
(Guide figure, e.g. 2.5 = approx.
25 °C) or time

Time segment timer

Comfort temperature
Off-peak temperature

Factory settings

Timer program switching times

Floor temperatures operating modes

Frost protection

1.0

=

^ approx. 10

Guide figure

°C

Off-peak temperature

1.8

=

^ approx. 18

Comfort temperature

2.5

=

^ approx. 25

Temperature setting limits
Max. Floor temperature

4.0

=

^ approx. 40

Min. Floor temperature

1.0

=

^ approx. 10

1.1 First start-up

After connecting to the mains supply, the following displays appear:

for approx. 5 seconds . . .

. . . then alternately

probe defective or not connected

1.2 Setting the time and day of the week

Press push-button M until the function symbol is displayed.

Hour

Push-
button

+

or

OK

Minutes

+

or

OK

Push-
button

Day of the week

+

or

OK

Push-
button

Displays

6

12

18

24

0

2.5

6

12

18

24

0

6

12

18

24

0

6

12

18

24

0

00:00

1 2 3 4 5

6

6

12

18

24

0

7

8

8

8

8

8

8

8

8

P

88:88

00

:00

00

:00

1

Advertising