Technical data, 3 set-back temperature – STIEBEL ELTRON RTF с 20.12.2004 User Manual

Page 5

Advertising
background image

5

English

Type

RTF

Switching Capacity

~ 12(2) A 230 V

Range

ca. 10 ºC . . . 45 ºC

Set-back (if required)

5 K

Switching Differential

1 K

H x W x D

81,5 x 81,5 x 44,5 mm

Class

ΙΙ

, acc. this manual

Protection rating

IP 20

Sensor cable length (DIN 44574)

4 m

Approvals

see print on unit

Sensor Values
Temperature R [kOhm] U [V]

20 °C

2,43

2,22

10 °C

3,66

2,49

40 °C

1,15

1,63

30 °C

1,65

1,92

50 °C

0,82

1,35

various frames which belong to the
controller.
To install the controller take the following
steps:
– Carefully remove the temperature

selection knob (2) with the help of a
screwdriver.

– Remove the locating screw (7) and

remove the cover (8) and frame (9).

– Connect the electrical connections in

accordance with the wiring diagram below
and as follows:
t The sensor probes are connected to

the 2 terminals marked ‘F’.

t The incoming mains electricity

connection should be connected as
follows;
y

Live to ‘L’

y

Neutral to ‘N’

y

Earth to Earth terminal on the back

box.

t The heating mats connections should be

as follows;
y

Live to ‘LH’

y

Neutral to ‘N’ (common with the

incoming mains supply)

y

Earth to Earth terminal on the back

box

– Fit the controller (10) into the back box

using the locating screw holes on the back
plate.

– Refit the frame (9) and cover (8).

The Instructions for the controller
and the under-floor heating should

be kept together.

2.3 Set-back Temperature

By using the terminal TA in conjunction with
an external time-switch or a switch, a set-
back facility, reducing the set temperature by
5K is possible.

3. Technical data

Advertising