TIMBERK Evolution WHP-5OS User Manual

Page 6

Advertising
background image

Water heater installation
- Remove the front panel of the water heater unscrewing the mounting
screw at the appliance bottom.
- Mark points for holes according to Fig.3.
- Drill four holes of appropriate depth, insert dowel pins.
- Turn screws at the top and make sure that there is certain distance be-
tween the screw head and wall (refer to Fig.3).
- Suspend the water heater onto the screws and turn two mounting
screws at the bottom; connect the power cord; install the front panel;
and turn the front panel screw.

Fig. 2

Fig. 3

Brick or concrete wall

NOTE:
Installation of the water heater in the operation place and arrange-

ment of a power supply line shall be performed by a specialized

organization, representatives of the manufacturer's service

department, or specialists having permits for installation of electric

equipment with observations of safety requirements.
If the installation and operation instruction manual of the water heater

is violated, the appliance is not subject to warranty service and the

manufacturer does not bears the responsibility.

Connection to water mains
- The water heater shall be directly connected to the water mains of cold
water supply with operating pressure from 0.08 to 0.6 MPa. If water pres-
sure in the mains exceeds 0.6 MPa, the feed system shall be fitted with a
reduction valve (pressure reducer) so that operating pressure does not
exceed 0.6 MPa.
- The water feed shutoff valve shall be installed upstream of the water
heater inlet (Fig. 4).
- Installation of a shutoff valve at the hot water outlet from the water heater
is prohibited (Fig.5).
- After installation of the water heater and before connection of power
supply, it is necessary to flush the system with water to remove any con-
taminations or free particles inside the water heater. If you do not perform
this, operability of the water heater may be affected.
- The inlet connection and hot water outlet are clearly marked on the appli-
ance with indication labels.
- Install the safety valve (included to the package)* at the cold water feed
connection in the position indicated by the arrow of water flow direction.
At that, the drain opening shall be directed downward and free for events
of emergency water drainage.
- To avoid water leakage during connection of any pipes, use the rubber
sealing gaskets included to the water heater package. The cold and hot
water connections are installed with the method of threaded joints (G1/2)
certainly using sealing cups* and a strainer (*included to the package).
- We RECOMMEND you to use a separate water filter at the cold water inlet
to extend service life of the heating element, if water hardness exceeds
450 mg/L (CaCO3).

www.timberk.com instant water heater

6

Advertising