9. Cleaning and maintenance of the unit
Prior to cleaning make sure that the plug is disconnected from an outlet.
Otherwise it may result in an electric shock.
Before cleaning, wait until water in the base device is completely cooled
down in order not to burn hands.
Clean the unit once or twice a week.
9.1 To wipe the external surface of the unit use a damp and soft cloth.
To prevent an electric shock do not scratch and do not damage unit s
elements upon cleaning.
When cleaning the unit, do not use solvents, benzine, dimethylbenzene, hard
brush, talc powder and other substances other than water.
9.2 Wipe water remains inside the base device under the tank by a damp
and soft cloth.

To remove water remains on small parts you can use the brush, and then wipe
them again with a soft cloth.
9.3 If there is dirt on the membrane, clean it by means of a brush.

9.4 Use a brush to remove water remains on the surface of the nozzle
and then wipe it again by a soft cloth.
9.5 Clean the water tank and the atomizer by pure water.
Clean the cap
carefully, without applying much effort, otherwise it may result in water
leakage through the cap.
Once water remains are removed from the surface of the atomizer, wipe it
by a soft cloth.
Clean the external surface of the unit by a damp and soft cloth.

10. Troubleshooting

In case of emergencies resort to troubleshooting methods, given in table 5.

Poor atomizing

(insufficient

performance)

Remedy

Defect

Possible cause

The unit is operating in

a light mode (low

atomizing frequency)

No defect. If necessary to switch to the intensive

mode, press «STEAM» button in

the manual setting mode and switch the unit

to the intensive operation mode.

Atomizer is clogged

Clean the atomizer

Tank water temperature

is too low

Set the maximum performance. Humidifier s

performance will be increased in 10 minutes

No atomizing

The plug is poorly

inserted into an outlet

Connect the plug into an outlet carefully

Red light on the water

indicator has illuminated

and went out (water

tank is completely empty)

Add water to the tank

A white residue appeared

on objects around the

humidifier (salts,

separating from water)

Lime deposits are formed

on the membrane

Clean the humidifiers membrane by a special brush

Water demineralization

cartridge is worn down

(ion exchange resin).

Inused water contains

a large amount a caleium

or magnesium.

Replace the cartridge.

No warm atomizing

Use of warm steam is

not selected

Press «HEART» button in the manual setting

mode and switch the unit to a warm steam

humidification mode

Operation has just started No defect. It will take about 10-20 minutes

for warm steam to be atomized (time, required

for water heating by the heater after

it s switched on)

Difference between the

level of current humidity

and readings of a

humidity recorder

is too big

Dirt accumulation

inside an air vent

Clean the air vent. Even in one room humidity

can be different depending on the location

The unit is operated in

places, where it is affected

by the environment,

for example, by a window

Install the unit in places, where it cannot be

affected by the environment

Steam has an

unpleasant odor

Signal 1 is given
Signal 2 is given

Not fresh water in use

Tank full sound signal
Fan operation

sound signal

There are remains of

not fresh water or litter

in the water groove

Clean the unit in accordance with the cleaning

and maintenance manual and fill it with fresh

water

No defect in the unit, keep on its operation

Table 5.

ENGLISH

Fig. 10

Fig. 11

11. Utilization

If you are unable to solve issues by means of mentioned methods,
contact a service center.Life of the humidifier is 2 years.
Upon expiration of the humidifier it must be disposed in accordance with
regulations, rules and by means, currently in force at a disposal station.