AC Input Voltage
AC Input Current

100-240VAC, 50-60Hz

5 - 2.5A

5 - 2.5A

DC OUTPUT

3.3V

5V

12V

-12V

5Vsb

Total Power

16A
14A
22A

0.3A
2.5A

16A
14A
26A

0.3A
2.5A

Rated

Combined

Rated

Combined

90W

90W

264W

3.6W

12.5W

300W

312A
3.6W

12.5W

350W

PROTECTION CIRCUIT

DC Rail

3.3V

5V

12V

Activated when output power > 110 ~150% of rated max load.

ENVIRONMENT

Operation ambient : 0~40

o

C (for full rated output)

Storage ambient : -20~70

o

C

Operation: 20% to 90% relative humidity, non-condensing

Storage: 5% to 95% relative humidity, non-condensing

OTHERS

One 12cm twist bearing fan, speed auto controlled.

150(w) x 86(h) x 140(d) mm
Around 2kg
CE / GOST

Over Voltage Protection

Over Power Protection

OVP trigger range

4.5V
7.0V

15.6V

> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25

o

C ambient

(MIL-HDBK-217F standard)

Temperature

Humidity

MTBF

Cooling

Dimension

Weight

Safety/ EMC

20+4P

20+4P

20+4P

20+4P

20+4P