Enermax Platimax EPM1500EGT User Manual

Page 3

Advertising
background image

2

ENERMAX Platimax Series Power Supply Specification

EPM1500EGT

EPM1350EWT

EPM1200EWT

AC Input Voltage

220-240VAC, 50-60Hz

110-240VAC, 50-60Hz

(Maximum range:

100-264VAC, 47-63Hz)

100-240VAC, 50-60Hz

(Maximum range:

90-264VAC, 47-63Hz)

AC Input Current

8-7A 14-6.5A

14-5.5A

DC Output

Rated

Combined

Rated

Combined

Rated

Combined

3.3V

0-24A

120W

0-24A

120W

0-24A

120W

5V

0-24A 0-24A 0-24A

12V1

0-30A

1500W

(125A)

0-20A

1350W

(112.5A)

0-30A

1200W

(100A)

12V2

0-30A 0-20A 0-30A

12V3

0-30A 0-30A 0-30A

12V4

0-30A 0-30A 0-30A

12V5

0-30A 0-30A 0-30A

12V6

0-30A 0-30A 0-30A

-12V

0-0.5A 6W 0-0.5A 6W 0-0.5A 6W

5Vsb

0-3A 15W 0-3A 15W 0-3A 15W

Total Power

1500W 1350W 1200W

Peak Power*

1650W 1600W 1440W

Protection Circuit

Over Current

Protection

DC Rail

OCP trigger range

3.3V

30 – 45A

5V

30 – 45A

12V1/2/3/4/5/6

40 – 50A

(DC)

Under Voltage /

Over Voltage

Protection

DC Rail

UVP trigger range

OVP trigger range

3.3V

2.0 – 2.4V

3.9 – 4.5V

5V

3.3 – 3.7V

5.7 – 6.5V

12V1/2/3/4/5/6

8.5 – 9.5V

13.3 – 14.5V

-12V

-9.5 – -10.5V

+5Vsb

5.7-6.5V

(AC)

Under Voltage Protection

Activated when AC input voltage < 70VAC.

Over Power

Protection

Activated when output power > 110 ~160% of rated max load.

Over Temperature

Protection

Activated when PSU heat sink > 90 ~ 110

o

C.

Short Circuit

Protection

Activated when any DC rails short-circuited.

Surge & Inrush

Protection

Sustain 2KV surge stroke.

Sustain up to 70A inrush current @ 240VAC at cold start.

ENVIRONMENT

Temperature

Operation ambient: 0~40

o

C

Storage ambient: -40~70

o

C

Humidity

Operation: to 85% relative humidity, non-condensing at 25

o

C

Storage: to 95% relative humidity, non-condensing at 50

o

C

OTHERS

MTBF

> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25

o

C

(MIL-HDBK-217F standard)

Dimension

150 (w) x 86 (h) x 180 (d) mm

Weight

2.25kg (without modular cables) ±50g

Safety

UL/cUL(Level 6), TUV, GOST, CB, BSMI(EPM1350&1200EWT)

EMC

CE, FCC, KCC

* Peak power may last up to 60 seconds.

Advertising