English, Description, Installation – Candy CSDH 9110 ZEN User Manual

Page 2: Operation

Advertising
background image

ENGLISH

DESCRIPTION

The hood may be in the filtering or the ducting version.

Filtering version (Fig. 1): The hood aspirates the kitchen air saturated with fumes and odours, purifies it through

the grease filter/s and charcoal filter and returns clean air into the room. For constant efficiency, the charcoal filter must
be replaced periodically. The charcoal filter is not supplied.

Ducting version (Fig. 2): The hood aspirates the kitchen air saturated with fumes and odours, passes it through the

grease filter/s and expels it to the outside through an outlet pipe. With this version the charcoal filter is not required. Decide
from the outset on the type of installation (filtering or ducting). For greater efficiency, we recommend you install the hood
in the ducting version (if possible).

INSTALLATION

ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified operator.

INSTALLATION IN DUCTING VERSION: Before fixing, the outlet pipe for air evacuation to the outside must be installed.

Use an outlet pipe with: – minimum indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified
material (according to the State); – an as smooth as possible inside. It is also advisable to avoid any drastic changes
in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside, follow all the other instructions
given on the “Warnings” sheet. Prepare the power supply within the telescopic chimney (for the electrical connection, follow
all the other instructions on the “Warnings” sheet).

1.

Fixing to the wall: Draw a line on the wall in vertical line with your hob. Mark the first 2 holes to be drilled in the

wall, respecting the distances indicated in Fig. 3. Drill the 2 holes and fit the screw anchors provided. As already specified
on the “Warnings” sheet, bear in mind that the distance between the lower edge of the hood and the hob must be min.
650 mm. Fix the metal bracket (A) to the wall using the 2 holes just drilled (Fig. 4); the screws for fixing the bracket are
provided. Use the 2 cut-out triangles on the bracket to position it exactly along the vertical axis of the hood. Hang the
hood on the bracket (Fig. 5). Adjust the horizontal position moving the hood to the right or left so that it is aligned with
the wall units. When adjustment has been completed, without removing the hood, mark the other 4 holes to be drilled (C)
in the wall. Remove the hood and drill the holes marked (8 mm diameter). Then use the 4 screw anchors and the 4 screws
provided for final fixing.

2.

Mount the plate of the electrical system fixing it with 2 screws (Fig. 6).

3.

Install the flange in the device air outlet and press slightly (Fig. 7).

4.

Fixing the telescopic flues: 4a - Adjust the width of the support bracket (D) of the telescopic flue by means

of the screws (E) as shown in Fig. 8; then, by means of the screw anchors and screws (F) provided, fix the bracket to
the ceiling in such a way that it is positioned along the axis with your hood.
4b - Connect the air outlet pipe to the air vent of the hood. - Use a flexible pipe and lock it to the air vent of the hood
with a metal hose clamp - Fig. 9 (pipe and clamp are not provided). - For exhaust hoods, turn the upper flue over so that
the air exhaust grid is in the lower section (Fig. 10).
4c - Plug in the hood. Insert the extension flues setting them on the hood; extend the upper flue to the ceiling and secure
with the 2 screws (H) - Fig. 11.

INSTALLATION IN FILTERING VERSION: Prepare the power supply within the telescopic flues (for the electrical

connection, follow all the other instructions on the “Warnings” sheet).

Fitting the charcoal filter: Turn the glass panel gripping it from the font part of the hood. Remove the grease

filter by pushing the catch towards the rear of the hood and turning the filter outwards (Fig. 12). Then fit the charcoal
filter (Fig. 13) by inserting the two filter clips in the slots and turning the filter towards the inside of the hood.

Fixing to the wall: for fixing to the wall refer to the instructions for the ducting version (see points 1, 2, 3), then continue

with the instructions below.

Fixing the telescopic flues: - Adjust the width of the support bracket (D) of the telescopic flue by means of the screws

(E) as shown in Fig. 8. - Then, by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in
such a way that it is positioned along the axis with your hood. - Mount the flange on the hood in correspondence to the
air outlet point (Fig. 14). - Take the air baffle and fit a flexible pipe to it (125 mm diameter) locking it with a metal hose
clamp (pipe and clamps are not provided). Fit the air baffle to the upper flue (Fig. 15) with 4 screws.
- Connect the flexible pipe to the flange on the air vent (Fig. 16). - Plug in the hood. Insert the extension flues setting
them on the hood; extend the upper flue to the ceiling and secure with the 2 screws H (Fig. 11).

OPERATION

Controls (Fig. 17):
A)
Turns the LIGHTS off
B) Turns the LIGHTS on.
C) Decreases speed down to minimum speed. If pressed for 2" the motor is turned off.
D) Activates the motor (calling the last speed used) and increases the speed until reaching maximum..