Boneco Air-O-Swiss Boneco D7064 User Manual

Page 19

Advertising
background image

19

en

Emptying the water reservoir

When the water reservoir is full, the appliance automati-

cally switches itself off and a signal is sounded, consisting

of 15 tones. LED [1] lights up and signals that the water

reservoir is full. The water reservoir should be emptied as

follows:

• Using both hands, push gently against the sides

of the reservoir and carefully pull it out.

• Pour away the water and carefully replace the

reservoir. The LED goes out.

Directions:

1. Do not remove the float from the water reservoir. The

sensor that measures the water level in the reservoir

will not work correctly without float. If that happens,

the reservoir could leak water.

2. If the water reservoir becomes dirty, you can clean

it with cold or lukewarm water. Do not use cleaning

or scouring products, chemically treated cloths, petrol,

thinner or other solvents, as these can scratch or

damage the reservoir which can lead to it leaking

water.

3. When replacing the water reservoir, push it firmly using

both hands into the correct position. If the reservoir is

not replaced correctly, the sensor will continue to show

«RESERVOIR FULL» and the dehumidifier cannot be

turned on.

Permanent water drainage

To allow the dehumidifier to operate with continuous water

drainage, the following measures should be taken (see

illustration):

1. Turn off the appliance and remove the plug from

the socket.

2. Open the hole for the water drainage pipe in the

water reservoir (by removing part A).

3. Push a water hose (outer diameter 14 mm, inner

diameter 10 mm) through the hole and connect the

hose to the water draining connection (part B).

4. Place the end of the hose in the drain. Make sure

the hose is not folded and is laying straight.

When using permanent drainage, the water

reservoir must remain in place.

A

B

1

14

15

16

27175 D7064-EU-Manual_vec.indd 19

7.6.2007 17:37:51 Uhr

Advertising