< 4.3 > QD Remote Control Connection & Operation

BYTE 2: Status code for alarm operations: The first 4 bits show the sensor activated alarm status of each

channel; next 4 bits show the video loss alarm status of each channel. The digit “1” means alarm event is

detected, and “0” means no alarm event is detected.

b7 - b4: Sensor Activated Alarm

b3 - b0: Video Loss Alarm

b7

b6

b5

b4

b3

b2

b1

b0

CH4

CH3

CH2

CH1

CH4

CH3

CH2

CH1

Sensor activated Alarm

0001 = CH1 activated

0010 = CH2 activated

0100 = CH3 activated

1000 = CH4 activated

Video Loss Alarm

0001 = CH1 activated

0010 = CH2 activated

0100 = CH3 activated

1000 = CH4 activated