Chapter Eight: Appendix

Two types of interfaces are available in the terminal: 9-pin RS232 interface

(for direct RS232 serial communication) and an RJ45 interface (for RS485
and TCP/IP over Ethernet communications).

8.1 RS232 Interface

The RS232 interface (refer to page 10 figure 4.1) provides RS232

communication, Lock and Wiegand entrance guide function with 9 pins

in total. Definitions of each pin are listed in the following table:

PIN

Definition

1

Reserved

2

RS232 TX

3

RS232 RX

4

LOCK Data 1

5

GND

6

Reserved

7

Data ()

8

Reserved

9

Reserved

timeQplus BIOMETRIC™ Terminal User Manual

37

8

timeQplus BIOMETRIC™ Terminal User Manual

3.2 Setup

With Setup highlighted, press OK to access the Setup level-2 menus

and browse the four items available. There are a total of 18 level-3

menus as per the diagram below. For more information on each

menu, please refer to page 26.

RS232 Communication Diagram

Note: For door access and/or access control applications: connect with

the pins four and five when using the simple entrance guard;
white connect pins four five and seven when adopting Wiegand output.

A typical RS232 connections diagram looks like the figure below:

*The card option is not available on standard units.

Level-1 Menu

Level-2 Menu

Level-3 Menu

Setup

Admin Record

Admin max number

Language

Time

Voice Out

Auto Shutdown

IP Address

Port number

Password

Duplicate Punches

Total Punches Alert

Device ID

Baud rate

Subnet Mask

Default

RS485

Ethernet

Display

Adjustment

Unlock

Communication

Setting

System Setting

Record Setting

AM/PM

Card*

Date Format