7.1.2.2.

RDR_to_PC_SlotStatus

This message is sent by the smart card reader in response to PC_to_RDR_IccPowerOff,
PC_to_RDR_GetSlotStatus

, PC_to_RDR_Abort messages and Class specific ABORT request.

Offset Field Size

Value

Description

0

bMessageType

1

81h

1

dwLength

4

00000000h

Size of extra bytes of this message

5

bSlot

1

Same value as in Bulk-OUT message

6

bSeq

1

Same value as in Bulk-OUT message

7

bStatus

1

Slot status register as defined in CCID
section 4.2.1

8

bError

1

Slot error register as defined in CCID
section 4.2.1 and this specification
section 5.2.8

9

bClockStatus

1

value =
00h

Clock running

01h

Clock stopped in state L

02h

Clock stopped in state H

03h

Clock stopped in an unknown

state
All other values are RFU.