7.1.2.3.

RDR_to_PC_Parameters

This message is sent by the smart card reader in response to PC_to_RDR_GetParameters,
PC_to_RDR_ResetParameters and PC_to_RDR_SetParameters messages.

Offset Field

Siz
e

Value Description

0

bMessageType

1

82h

1

dwLength

4

Size of extra bytes of this message

5

bSlot

1

Same value as in Bulk-OUT message

6

bSeq

1

Same value as in Bulk-OUT message

7

bStatus

1

Slot status register as defined in CCID section
4.2.1

8

bError

1

Slot error register as defined in CCID section
4.2.1 and this specification section 5.2.8

9

bProtocolNum

1

Specifies

what

protocol data structure follows.

00h = Structure for protocol T=0
01h = Structure for protocol T=1
The following values are reserved for future
use.
80h = Structure for 2-wire protocol
81h = Structure for 3-wire protocol
82h = Structure for I2C protocol

10

abProtocolData
Structure

Byt

e

arra

y

Protocol Data Structure as summarized in
section 5.2.3.

7.1.3.

Commands Accessed via PC_to_RDR_XfrBlock

7.1.3.1.

GET_READER_INFORMATION

This command returns relevant information about the particular smart card reader model and the
current operating status such as the firmware revision number, the maximum data length of a
command and response, the supported card types, and whether a card is inserted and powered up or
not.

Note: This command can only be used after the logical smart card reader communication has
been established using the SCardConnect( ) API. For details of ScardConnect( ) API,
please refer to PC/SC specification.

Pseudo-APDU

CLA

INS

P1

P2

Lc

FF

H

09

H

00

H

00

H

10

H

Command format (abData field in the PC_to_RDR_XfrBlock)