6.0. USB Interface

The ACR83 (CCID) is connected to a computer through a USB port following the USB standard.

6.1. Communication Parameters

The ACR83 (CCID) is connected to a computer through USB as specified in the USB Specification

1.1. The ACR83 (CCID) is working in full-speed mode, i.e. 12 Mbps.

Pin Signal Function

1

VBUS +5 V power supply for the reader

2

D-

Differential signal transmits data between ACR83 and PC

3

D+

Differential signal transmits data between ACR83 and PC

4

GND

Reference voltage level for power supply

Table 1: USB Interface Wiring


Note:
ACR83 PINeasy is a PC/SC Device. In order for the ACR83 (CCID) to function properly

through USB interface, an

ACS PC/SC driver has to be installed. Please refer to the Device Driver

Installation Guide for more details.

6.2. Endpoints

The ACR83 (CCID) uses the following endpoints to communicate with the host computer:
Control Endpoint

For setup and control purpose

Bulk OUT

For command to sent from host to ACR83 (CCID) (data packet size is 64

bytes)

Bulk IN

For response to sent from ACR83 (CCID) to host (data packet size is 64

bytes)

Interrupt IN

For card status message to sent from ACR83 (CCID) to host (data packet

size is 8 bytes)