ARIETE Twin Aqua Power 2477 User Manual

Page 24

Advertising
background image

• Inadequate suction power

Washing cleaning
• The suction power decreases

suddenly

• Unusual heavy development of

foam in the dirty water tank

• No cleaning liquid is provided

although the pump is switched
on

• Is residual moisture to high,

liquid is no longer sucked up
properly

lease any dust and dirt blocking the tube and clear the
stoppage.

- Is the filter blocked?  Clean the filters.
- Are nozzles, suction tube or suction hose blocked by co-

arse dirt?  Flexing the tube during operation will rele-
ase any dust and dirt blocking the tube and remove the
stoppage.

- Is the housing cover properly locked?  Check.
- Is the electronic suction power controller set to MIN? 

Set suction power to MAX (orange lamp lights up).

- Is the mechanical suction power controller on the hand

grip open?  Close the slider on the hand grip.

- Is the dirty water tank full (float has responded)?  Em-

pty and clean the tank.

- Have you used original Ariete cleaning shampoo?  Re-

place.

- Is there any cleaning liquid in the spraying agent tank?

Refill.

- Is the spraying nozzle blocked?  Replace nozzle for

some time in luke-warm water and after-wards draw out
strongly.

- Is the tank connection opening blocked?  Remove fresh

water tank and thoroughly suck out the tank connection
opening (connection point between fresh water tank and
housing) with the crevice nozzle to remove any possible
contamination and dirt.

- Is the electronic suction power controller set to MIN? 

Set suction power to MAX (orange lamp lights up).

- Is the mechanical suction power controller on the hand

grip open?  Close the slider on the hand grip.

- Is the nozzle really flat on the floor?  Hold nozzle or

suction cleaning with a slightly greater incline.