4. IGNITION POWER MANAGEMENT

Startup/shutdown conditions from the IGNITION signal:

IGNITION startup signal must be valid during 5 sec. (anti noise protection).

IGNITION shutdown – IGNITION signal must be inactive during 5 minutes,
then PIC controller initiate Power Button signal (OS must be set to shutdown
from the Power Button). It generate Main Button shutdown event and then
goes to complete power off.


Typically the system can start only from IGNITION signal, because startup PIC
controller is disconnected from the power source.

The system can be switched off from:

Power IGNITION OFF signal.

ACPI OS shutdown

Power Button – generate ACPI event (OS dependent).

Power Ignition Startup Procedure

Power Ignition Shutdown Procedure


5. POWER MANAGEMENT

Power-off delay time is selectable by BIOS to disable and enable in 5 min
/2hr/4hr /12hr

Ignition On/Off status detectable by SW

If the ignition is off and the system is still on after 5 minutes, PowerBrick5.0-i3
will shut down automatically.

If the ignition is turned on again and the power-off delay is in progress,
PowerBrick5.0-i3 will cancel the delay function and will continue to operate
normally.

If the ignition is turned on again and the power-off delay ended,
PowerBrick5.0-i3 will shut down completely will power-on again automatically.




6.

POWER INPUT CONNECTOR

Power Brick5.0'-i3's Power Wiring Diagram

4


1 GND 2 DC+ iN 3 IGNITION

10A

Computer connector :

pin1-Ground
pin2-DC+ 9~32V
pin3-Ignition

For surepower, connect pin1 and pin3
togather

5

Advertising