ACU-RITE ENC 150 (New Style) User Manual

Page 10

Advertising
background image

1/4-20 x 1” BHCS
with encoder washer

A variety of mounting conditions can be accommodated.

• The machine configuration determines the brackets required to

install the linear encoder.

• Three typical mounting conditions are shown; flush, offset, and

backup spar (as shown previously on page 4).

• The 8-32 SHCS fastener lengths shown on this page are supplied

with the encoder hardware.

• The 8-32 SHCS for mounting the reading head is a standard low

head style fastener.

• Mounting surfaces are offset.
• Installation without backup spar.
• Use leveling screws in place of spacers or shims.

• Mounting surfaces are flush within .005”.
• The reading head leveling screws are not required.

• Flush or offset mounting surfaces with a backup spar.
• Bracket used to reduce head to mounting surface gap.
• Use reading head leveling set screws.

ACU-RITE

®

8

Typical Mounting (s)

ENC 150

Backup spar with bracket

Offset surfaces

1/4-20 x 1” BHCS
and encoder washer

8-32 x 3/4” SHCS

Flush surfaces

ll .005

0.0 ± .005

8-32 x 3/4” SHCS

Space of < .18” use reading head
leveling set screws.

1/4-20 x 1/2” BHCS
and spar washer

8-32 x 5/8” SHCS
(trim if necessary)

1/4-20 x 1/2”
BHCS and washer

A space >.18”, use a spacer or
bracket (shown); <.18” use
leveling set screws.