Bosch GLM 80 + R 60 Professional User Manual

Page 22

Advertising
background image

22 | English

2 609 141 088 | (7.8.13)

Bosch Power Tools

To select the reference level, press button 10 until the re-
quested reference level is indicated on the display. Each time
after switching on the measuring tool, the rear end of the
measuring tool is preset as the reference level.

Subsequent changing of the reference level for measure-
ments that have already been carried out (e.g. when indicat-
ing measuring values in the measured-value list) is not possi-
ble.

“Basic Settings”

To access the “Basic settings” menu, press and hold the basic
settings button 4.
Briefly press the basic settings button 4 to select the individ-
ual menu items.

Press the minus button 5 or the plus button 11 to select the
setting within the menu items.

To exit the “Basic settings” menu, press the measurement
button 2.

With exception of the “Permanent laser beam” setting, all ba-
sic settings are retained when switching off.

Continuous Laser Beam
Do not point the laser beam at persons or animals and

do not look into the laser beam yourself, not even from
a large distance.

In this setting, the laser beam also remains switched on be-
tween measurements; for measuring, it is only required to
press the measuring button 2 once.

Measuring Functions

Simple Length Measurement
For length measurements, press button 12 until the “length
measurement” indication appears on the display.

To switch the laser on and for measuring,
briefly press the measuring button 2 once
each time.

The measured value is displayed in the re-
sult line c.

For several subsequent length measurements, the last meas-
ured results are displayed in the measured-value lines a.

Area Measurement
For area/surface measurements, press button 12 until the in-
dicator for area measurement

appears on the display.

Afterwards, measure the length and the width, one after an-
other, in the same manner as a length measurement. The laser
beam remains switched on between both measurements.

Upon completion of the second measure-
ment, the surface is automatically calcu-
lated and displayed in the result line c.
The individual measured values are dis-
played in the measured-value lines a.

Volume Measurement
For volume measurements, press button 12 until the indica-
tor for volume measurement

appears on the display.

Afterwards, measure the length, width and the height, one af-
ter another, in the same manner as for a length measurement.
The laser beam remains switched on between all three meas-
urements.

Upon completion of the third measure-
ment, the volume is automatically calcu-
lated and displayed in the result line c.
The individual measured values are dis-
played in the measured-value lines a.
Values above 999999 m

3

cannot be indi-

cated; “ERROR” appears on the display.

Divide the volume to be measured into individual measure-
ments; their values can then be calculated separately and
then summarized.

Continuous Measurement (Tracking) / Minimum/Maxi-
mum Measurement (see figure B)
For continuous measurements, the measuring tool can be
moved relative to the target, whereby the measuring value is
updated approx. every 0.5 seconds. In this manner, as an ex-

Basic Settings

Tone Signals

On

Off

Display Illumination

On

Off

Auto on/off

Digital vial

On

Off

Display rotation

On

Off

Permanent laser beam

On

Off

Unit of measure, distance
(depending on country ver-
sion)

m, ft, inch, ...

Unit of measure, angle

°, %, mm/m

OBJ_BUCH-1347-005.book Page 22 Wednesday, August 7, 2013 4:12 PM

Advertising
This manual is related to the following products: