Level Sensors (see figure J)
Clean the level sensors 37 occasionally.
– Unlock the latches 13 and remove the vacuum lid 12.
– Clean the level sensors 37 with a soft cloth.
– Reattach the vacuum lid 12 again and lock the latches 13.

Storage and Transport (see figure K)
– Wind the mains cable around the cable holder 17.
– Insert the accessories into the holders provided: Vacuum

tubes 31 in holders 19, crevice nozzle 27 in holder 20,
floor nozzle 30 in holder 21.

– Undue the elastic tie-downs of the vacuum-hose holders 4

and place the vacuum hose 24 around the vacuum cleaner

lid into the holders 4.
Reattach the elastic tie-downs.

– Mount the L-Boxx onto the retainers 11.
– To prevent back injuries, remove a full disposal bag or dust

bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 10.

– For transport of the vacuum cleaner, screw the plug cap 2

onto the hose connection piece 3.

– Store the vacuum cleaner in a dry room and secure it

against unauthorised use.

– To lock the castors 16, actuate the castor brakes 15 by

pushing down.

Correction of Malfunctions

Problem

Corrective Measure

The vacuum turbine does not start.

– Check mains cable, mains plug, fuse, socket outlet and filling-level sensors 37.

Mode selector switch 7 set to “Start/Stop automatic”.
– Set mode selector switch 7 to the “vacuum” symbol and switch the power tool con-

nected to the socket outlet 5 on.

Vacuum turbine switches off.

– Empty container 1.

Vacuum turbine does not restart after
emptying the container.

– Switch vacuum cleaner off and wait 5 seconds; switch on again after 5 seconds.

– Clean level indicators 37 as well as the space between the level indicators 37 with a

brush.

Vacuuming power decreases.

– Remove clogs from vacuum nozzle, vacuum tubes 31, vacuum hose 24 or flat-fold fil-

ter 26.

– Replace disposal bag 25 or dust bag.

– Engage filter cover 36 properly.

– Mount vacuum cleaner lid 12 properly and lock latches 13.

– Replace flat-fold filter 26.

Dust escapes during vacuuming

– Check proper installation of the flat-fold filter 26.

– Replace flat-fold filter 26.

The automatic shut-off (wet vacuum-
ing) does not respond.

– Clean level indicators 37 as well as the space between the level indicators 37 with a

brush.

The automatic shut-off does not function with non-conductive liquids or foam/bubbles.
– Monitor the level continuously.

The alarm sounds.

Vacuum capacity set too low.
– Set control knob for vacuum capacity 8 to a higher value.

Hose diameter is incorrectly set.
– Set airflow regulator 6 to correct vacuum-hose diameter.

Vacuum hose 24 clogged or bent/creased.
– Correct clog or bend/crease.

Disposal bag/dust bag full.
– Replace disposal bag 25 or dust bag.

Flat-fold filter 26 contaminated.
– Clean flat-fold filter or replace, as required.

Insufficient airflow for the connected power tool.
– Open air diffuser 34 of the tool sleeve 22:

Turn ring on tool sleeve until air-diffuser opening is completely opened.

– If available: Open air-diffuser opening of power tool.

Malfunction of the monitoring electronics.
– Contact an authorised service agent for Bosch power tools.

OBJ_BUCH-1715-002.book Page 22 Wednesday, July 24, 2013 2:28 PM