Recon tm magnet systems – American Magnetics CRYOGEN FREE SUPERCONDUCTING MAGNET SYSTEMS User Manual

Page 4

Advertising
background image

ReCon TM Magnet Systems

Based on heat load and size of the superconducting magnet
either a dry conduction cooled or ReCon

TM

style geom-

etry is recommended. ReCon

TM

style magnet systems use

cooling power of a closed cycle 4K cryocooler to recon-
dense gaseous helium back into the liquid Dewar. The
evaporating gas is liquefied in a thermodynamically ef-
fective manner and the cryocooler is strategically located
in the Dewar. The first stage of the cryocooler is used to
cool the shields of the Dewar thereby eliminating the need
for any liquid Nitrogen. ReCon

TM

magnet systems offer

combined benefits of traditional LHe systems with near
zero helium boil-off. These style systems are ideally suited
for retrofitting existing magnets and sample inserts into
a re-engineered Dewar with a suitable gas handling sys-
tem. Pulse tube cryocoolers are ideal for applications that
desire lower vibrations.

200mm RTB ReCon system

ReCon

TM

solenoid systems available in vertical or horizontal geometries with

fi elds up to 16T and wide bore sizes

ReCon Maxes

TM

systems are available with vector fi elds up to 6T

ReCon OptiMAxes

TM

systems are available in 2 or 3-axis geometries

ReCon

TM

split coil systems available in optical and non-optical confi gurations

with fi elds up to 10T

ReCon

TM

systems with customized gas handling system is available with 1.5K/

He3 insert or with a dilution refrigerator

Advertising