Installation – American Magnetics 05500PS-430-601 High Stability Integrated Power Supply System User Manual

Page 41

Advertising
background image

Rev.

5

23

Installation

Power-Up Procedure

3. Energize the Model 430 Programmer by placing the power switch

in the

I (ON) position.

Note

Ensure the Model 601 energy absorber power adapters are properly

connected to the energy absorbers and their respective AC power

receptacles.

4. When prompted by the Model 430 Programmer, energize the power

supplies and press ENTER on the Model 430 Programmer.

Note

Remember to adjust the programmer Voltage Limit settings as

necessary to account for the additional voltage (5 V) required to

operate the system with a Model 601 installed.

Warning

All power supply parameters, both hardware and software, have

been set at the AMI factory. Power supply control, with the exception

of powering

ON

and

OFF

, is done by way of the AMI Model 430

Power Supply Programmer. No field adjustments or reconfiguration

of the power supply should be attempted in the field unless

specifically described in this document or recommended in writing

by an AMI Technical Support Representative.

5. Enter a stability setting of 100%. Refer to sections 3.3 on page 31

and 3.7.9 on page 45.

6. Verify the various setup menu values for the system (with the

exception of the stability setting, which is to be temporarily left at

100%). If the power supply system was purchased with an AMI

magnet, AMI has preset the setup menu values for proper

operation. See sections 3.3, 3.5, 3.9 and 3.10 for more discussion of

the setup menu values and their entry into the Model 430

Programmer.

7. Set the Model 430 Programmer to display current (rather than

field). Refer to sections 3.2.1 and 3.7.5.

8. Set the ramp rate to 1 A/sec. Refer to sections 3.3 on page 31 and

3.7.1 on page 39.

1. If the system shipped with CamLoc quick-disconnect connectors, they may be

quickly disconnected from the magnet leads and connected together.