PROTECTION

Every model in the CXA-Series incorporates protection features.

The front panel Protection LED indicates the activity of the

speaker connection relay circuitry in each channel.When the

protection LED turns on, this circuitry is active, and all connected

speakers are muted.

Initial power-up : For approximately five seconds after initial

power-up, the protection circuitry is activated and the speaker

outputs are muted. If everything is operating normally, you will

hear an audible click at the conclusion of this brief period, as

the protection circuitry is deactivated and the unit begins

delivering signal to the connected speakers. It is normal for the

Protection LED to fade gradually after the amplifier is powered

off.

Thermal Protection : Abnormally high heat sink temperatures

will engage the protection circuitry for the overheating channel

only. An output relay disconnects the speakers until normal

temperature range is restored. The Protect indicator will light

to show the protection circuit is active. To guard against this

problem, make sure the unit receives adequate ventilation on all

sides and that both the front and rear panels are unobstructed.

If the power transformer gets too hot, its thermal switch will

disconnect all of the secondary power and disconnect both

channel outputs.

Short circuit : If output is shorted due to faulty wiring, the

thermal circuitry will automatically protect the amplifier. If this

occurs, the load will be disconnected by the thermal protection

circuitry.

DC Voltage Protection : If an amplifier channel detects DC

voltage at the speaker output, the output relay will immediately

open to prevent speaker damage.

Subsonic Frequency Protection : The built-in High Pass Filter

provides subsonic frequency protection for each channel.

Current limiting Protection : At the amplifier’s full power limit,

or clipping point, the limiter circuitry will be activated. This is

indicated by illumination of the Clip LED. The channel gain is

automatically reduced, protecting the speakers from high

power. Uncontrolled feedback, oscillations, or improper

equipment gain setting may activate this circuitry, which is

virtually transparent in operation as full signal bandwidth is

maintained.

There is reason to be concerned any time the Protection LED

lights up (except for initial power-up during approximately five

seconds). If this occurs, turn the amplifier off immediately and

SETUP

Clipping is the result of an amplifier running into power supply

limitation. The maximum output voltage that any amplifier can

produce is limited by its power supply. Attempting to output a

voltage (or current) level that exceeds the power supply limit

will result in a flattening effect on the signal. A clipped waveform

exhibits extreme harmonic distortion, making it sound harsh or

dissonant. The clip limiter detects this and reduces the gain to

minimize the amount of overdrive. To preserve as much of the

program dynamics as possible, limiting reduces the average

program level until peaks barely clip. Each channel has its own

clip limiter, which can be switched on or off. When driving full-

range speakers, clip limiting reduces high frequency distortion

caused by bass overload. It also protects higher frequency

drivers from excess overdrive and harsh clipping harmonics.

Also known as a low-cut filter, a High Pass Filter rolls off signals

below 40Hz. The reproduction of the signal’s bass portion is thus

optimized, since ultra-low, distracting frequencies are

eliminated, and more power is available for the reproduction of

the wanted segment of the signal.

You should set up the filters so they best suit the frequency

response of your speakers, since some speakers are particularly

sensitive to over-excursion. The 40Hz filter works well with most

compact full-range speakers.

Clip limiter

HPF (Hi-Pass Filter)

Limiter

4