2 operational menu, Rst cam, Sync to – EVS XSense Version 10.04 - January 2011 Operating Manual User Manual

Page 38: 2nd ctrl, Perational

Advertising
background image

XSense – Version 10.04 – Operating Manual

EVS Broadcast Equipment – January 2011

Issue

10.04.A


29

7.1.2 O

PERATIONAL

M

ENU

The operational menu in Multi PGM mode gives access to the functions detailed in
the following paragraphs:

Rst Cam

This function restores the position of cameras on the active channels: CAM A on

PGM1, CAM B on PGM2, etc.

Note

When a clip/playlist is loaded on a channel, switching back to Live mode
will recall the record train, which was last used on that output. This
avoids too frequent uses of the Rst Cam function.

Sync To

This button allows you to synchronize the selected PGM in use with another one.
Press this button and then select the PGM to be used as a reference. This
function is not available with network trains.

2nd CTRL

This function allows the operator to swap the control of one or several play

channels between the EVS remote and a third-party controller. Both controllers
receive permanently the status of the channel(s), but only one controller at a time
is able to actually control a channel. The secondary controllers are defined in
Section 7 of the remote Setup Menu.

Press this function to enter the 2nd CTRL menu, select the channels that you want
to pass to the secondary controller by pressing the corresponding A, B or C key,

then press D (DONE) to validate your selection. Do the same to bring the control
of a channel back to the EVS remote.

Advertising