If the playlist is in PAUSE or EDIT mode, the element on which a jump-on-time is
defined will be played with the speed defined for it but without its transition parameters
(A/V effect and duration).

If the playlist is loaded on a channel later than the time defined for the jump-on-time,
the playout of the element will not be triggered.

When a playlist is being played, the "remaining time until next transition" and
"remaining time until next break", will be adapted taking into account the jump-on-time
condition.

Limitation for the Use of Jump on Time and/or Start
on Time

Several triggers cannot be defined for the same playlist element, i.e. two jump-on-time
conditions, two start-on-time conditions or a start-on-time condition and a jump-on-
time condition.

Defining a new condition will remove or overwrite the first one.

Several triggers with the same time and date cannot be defined for the same playlist.

Two triggers cannot be defined for the same playlist if their respective time and date
are too closed to each other, i.e. in the range [time-guardband, time+guardband].

Define Still/Start Mode Window

Opening of the Window

When right-clicking on a playlist element and selecting Define Start mode from the
Playlist Element contextual menu, the Define Still/Start Mode window opens.

90

1. Playlist Panel

EVS Broadcast Equipment S.A. - November 2012

Issue 6.00.B