5 rs422 #5, 6 rs422 #6, 7 id type – EVS XSense Version 10.03 - July 2010 Configuration Manual User Manual

Page 77: Rs422 #5, Rs422 #6, Id type, 5 rs422, 6 rs422, 7 id

Advertising
background image

Issue
10.03.A

XSense – Version 10.03 – Configuration Manual

EVS Broadcast Equipment SA – July 2010

70

3.14.5 RS422

#5

Possible values: Sony BVW75, XtenDD35, Odetics, VDCP, EVS AVSP, EVS IPDP,
Edit Rec, ---------

Default: Sony BVW75

3.14.6 RS422

#6

Possible values: Sony BVW75, XtenDD35, Odetics, VDCP, EVS AVSP, EVS IPDP,

Edit Rec, Touch Screen, ---------

Default: Touch Screen

Note

It is preferable to assign all EVS remotes to the first RS422 ports.

Avoid interleaving protocols and EVS remotes in this list.

The Touch Screen can only be assigned to RS422 port #6.

3.14.7 ID

T

YPE

Possible values: ID LSM (default) / UmID

Defines the type of clip ID used by RS422 protocols (XtenDD35, Odetics, Louth

VDCP, EVS AVSP) to identify clips:

ID LSM: It identifies clips using their page, bank, clip and camera number (ex:

245C).

UmID: It is another identifier that is either assigned by the protocol when

creating the clip (ex: CLP00001), or defined automatically by Multicam when the
clip is created using the EVS Remote Panel, or when the protocol doesn’t
specify this ID.

When it is defined by Multicam, the UmID is a coded ID (ex: 3x2QogRW) that
is unique for every clip created on any server, and is based on the serial

number of the server, and creation date and time of the clip.

Advertising