Longacre 78295 Digital Caster_Camber Gauge with AccuLevel (version 4) and QuickSet Adapter User Manual

Warning, Quickset, Digital caster/camber gauge

Advertising
background image

Instructions For No. 78295

QuickSet

Digital Caster/Camber Gauge

ADJUSTING THE

QuickSet™

TO YOUR RIMS: Unfold the lower arms until they stop. To adjust

the feet to your rim: Hold against the rim with the gauge at approximately spindle centerline.

Select one of the threaded holes on the lower arms that is closest to the outer lip of your rim.

Move both feet to these holes and hand tighten. Now loosen the upper foot and slide it up until

it also touches the outer lip of your rim. Hand tighten. At this point

QuickSet™

should just fit

inside the outer lip of your rim with very little clearance.

1) Find a level place to set up your front end. This unit reads camber and caster very accurately.

Unlevel ground will affect that accuracy.

2) Hold the

QuickSet™

against the wheel and rotate the gauge until the small vial on the top

of the gauge shows level.
BE SURE WHEELS ARE POINTED STRAIGHT AHEAD WHEN SETTING CAMBER.

3) CAMBER: Turn on the

AccuLevel™

Digital Readout by pushing “

ON/OFF

. Camber is

read directly on the display to .1

O

(1/10

O

). See separate

AccuLevel™

instructions if

needed. On the left side of the display a pointing up indicates negative camber (top of tire

in). A pointing down indicates positive camber (top of tire out). Race cars usually use nega-

tive camber on the RF and positive camber on the LF.

4) CASTER is measured with the

AccuLevel™

. First turn the wheels 15

O

to the right when

setting the RF or 15

O

left when setting LF. Rotate the gauge until level. The 15

O

must be done

accuretely. An error of even 1 or 2

O

turning will give a caster error.

5) Turn on the

AccuLevel™

and push CASTER, then ZERO. The display will ‘flash’. Now

turn the wheels back past center to 15

O

the opposite way - for a total of 30

O

. Rotate the gauge

again to level. Read the Caster directly on the

AccuLevel™

to 1/10

O

.

CASTER NOTE:

This amount of sweep - 15

O

- is different from vial type gauges.

6) Adjust the caster and camber as needed. Each time you make a change bounce on the front

end to settle the suspension. NOTE: Adjusting the caster may have an effect on the camber and

vice versa. Tighten bolts & double check

all settings.

.

.

Warning:

Do Not leave the gauge in the hot sunlite
or store in a place over 120

O

F. The digi-

tal display may not be readable.

Once it cools down the digital display should be visable again.

Replacements for broken vials can be ordered from any autho-

rized dealer or the factory. Replacement is quick and simple with

no loss of accuracy.

Monroe, Wa 360 453 2030 www.longacreracing.com

10/07 Ver. 4

15

O

15

O

DIGITAL CASTER ONLY

Turn wheels 15

O

each way

when setting Digital caster

See separate instructions for

AccuLevel™

if

needed. It can be removed and used for other mea-
surements. Simply slide

AccuLevel™

out (it’s

held in place with magnets).

NOTE: If display flashes on and off

AccuLevel™

is in Caster mode and will not read absolute angles
correctly. Push

CASTER button to exit Caster Mode.

Advertising