Discharge Characteristics (25ºC, 77ºF)

Physical Specification

Internal Resistance mΩ

Dimensions (mm)

Standard terminal (mm)

Power-Sonic Europe Limited

3 Buckingham Square, Wickford, Essex, SS11 8YQ

Tel: +44 (0)1268 560686 Fax: +44 (0)1268 560902

[email protected]

www.power-sonic.co.uk

PS-12260 VO

Nominal Voltage

Nominal Capacity (20HR)

12V

26 AH

Dimension

Weight

Standard Terminal

T12

Approx 7.9kg

Rated

Capacity

Capacity

Affected by

Temperature

26.00AH
24.20AH

24.24AH
22.10AH
16.30AH

Cycle

Standby

C

o

n

s

ta

n

t

V

o

lt

a

g

e

C

h

a

rg

e

Initial Charging Current
Less than 6.5A
Voltage 14.40V ~ 15.0V
at 25°C (77°F)

Recommended Charge
Current less than 6.5A
Voltage 13.5V ~
13.8V at 25°C (77°F)

40°C (104°F)

25°C (77°F)

0°C (32°F)

103%

100%

86%

Rev2 03/12

166 2

1

7

6

2

140 2

1

6

11

1

2

5

2

1

1

2

2

14.0 mΩ

(10yr Design Life in Float Service at 20°C)

In the event of further technical development we reserve the right to alter our design, specification and price without notice. E&O.E

20hr Rate(1.80V/cell)
10hr Rate( 1.80V/cell)

8hr Rate( 1.75V/cell)
5hr Rate( 1.75V/cell)

1hr Rate(1.60V/cell)

12

M5

6

T12 Threaded Insert 5mm Stud

Torque 2.0 -3.0 Nm

Length

Width

Container Height

Height to Terminal

166

175

125

118

2 mm

2 mm

2 mm

2 mm

+

-

+

-

+

+

-

F.V/Time

5MIN

10MIN

15MIN

20MIN

30MIN

45MIN

1HR

2HR

3HR

4HR

5HR

6HR

8HR

10HR

20HR

1.85V/cell

49.5

38.0

31.5

27.2

21.1

15.5

13.1

7.73

6.05

4.92

4.01

3.48

2.81

2.35

1.29

1.80V/cell

66.5

48.6

38.1

32.2

24.8

18.0

14.6

8.44

6.51

5.25

4.31

3.73

2.98

2.42

1.30

1.75V/cell

74.9

53.4

41.6

34.6

25.8

18.7

15.3

8.75

6.63

5.37

4.42

3.84

3.03

2.48

1.31

1.70V/cell

82.5

58.2

44.4

36.4

26.8

19.5

15.8

8.97

6.81

5.51

4.53

3.92

3.07

2.53

1.34

1.65V/cell

91.0

62.8

47.2

38.7

28.3

20.0

16.2

9.10

7.11

5.70

4.66

4.00

3.12

2.58

1.35

1.60V/cell

100.4

68.2

50.5

41.2

29.9

20.8

16.3

9.49

7.32

5.88

4.81

4.09

3.15

2.61

1.36

F.V/Time

5MIN

10MIN

15MIN

20MIN

30MIN

45MIN

1HR

2HR

3HR

4HR

5HR

6HR

8HR

10HR

20HR

1.85V/cell

90.50

70.20

58.80

51.30

40.10

29.80

25.20

15.00

11.80

9.62

7.87

6.84

5.54

4.64

2.55

1.80V/cell

120.20

88.70

70.10

59.80

46.60

34.40

28.10

16.30

12.60

10.20

8.40

7.31

5.86

4.78

2.57

1.75V/cell

132.70

95.90

75.60

63.70

48.00

35.40

29.30

16.80

12.80

10.40

8.60

7.49

5.95

4.90

2.59

1.70V/cell

142.00

102.10

79.60

66.40

49.70

36.60

30.10

17.20

13.10

10.70

8.80

7.63

6.03

4.99

2.64

1.65V/cell

154.40

109.20

84.00

70.10

52.00

37.20

30.60

17.40

13.60

11.00

9.01

7.77

6.11

5.09

2.67

1.60V/cell

166.40

115.90

88.30

73.80

54.50

38.60

30.70

18.00

14.00

11.30

9.27

7.92

6.15

5.14

2.68

Constant Current Discharge Characteristics Unit: Amperes (25ºC, 77ºF)

Constant Power Discharge Characteristics Unit: (Watts/cell) (25ºC, 77ºF)