Final check – Spicer Single Drive Axles Service Manual: S170, S190, S590 User Manual

Page 62

Advertising
background image

58

Lubrication

*Pinion pointing upward



Horizontal Mounting

12° Installation

12° Installation with Standpipe

Note: Grades must be continuous or lengthy in nature. Moni-

tor oil temperatures before installing standpipes. Axles
should operate at approximately 100°F (38°C) over
ambient temperature and not exceed 240°F (116°C).

Final Check

Prior to putting vehicle back into service, run the vehicle to
bring axle lube up to temperature. Check filler and drain plugs
and axle joint for leakage. Re-tighten to specifications as nec-
essary.

Tandem Rear Axles

Installation
Angle*

5-10%
Grade

10-15%
Grade

15-20%
Grade

1.00"

1.00"

1.75"

1.75"

2.00"

10°

2.00"

2.25"

13°

1.00"

2.25"

2.75"

15°

2.00"

2.50"

3.25"

1

2

1 - Oil Filler Hole
2 - Lost Oil Capacity

1

2

1 - Oil Filler Hole
2 - Lost Oil Capacity

2

1

1 - Oil Filler Hole
2 - Additional Oil Capacity

Advertising