Angle size – Spicer Driveline Installation Service Manual User Manual

Page 15

Advertising
background image

12

Installation Techniques

Compound Angle

Vibrations

Angle Size

The magnitude of a vibration created by a universal joint operating angle is proportional to the size of the universal joint operating
angle. Spicer Engineers recommend true universal joint operating angles of 3 degrees or less.

Obtain the true universal joint operating angle, as explained above, and if it is greater than 3 degrees, compare it to this chart.

The angles shown on this chart are the maximum universal joint operating angles recommended by Spicer Engineers and are di-
rectly related to the speed of the driveshaft. Any universal joint operating angle greater than 3 degrees will lower universal joint
life and may cause a vibration. Remember to check maximum safe driveshaft RPM by using the Spicer Safe Operating Speed Cal-
culator.

Driveshaft Maximum

Interaxle

RPM

Operating Angle

Parallel

Intersecting

5000

3.2°

-

-

4500

3.7°

-

-

4000

4.2°

3.8°

3.8°

3500

5.0°

4.4°

4.4°

3000

5.8°

5.1°

4.8°

2500

7.0°

6.0°

4.8°

2000

8.7°

6.0°

4.8°

1500

11.5°

6.0°

4.8°

Advertising