Veris Technologies 3150 Soil EC Mapping System - Trouble-shooting User Manual

Page 4

Advertising
background image

Remove the signal cable from the EC Surveyor and connect it to the terminal on the test
box. If you have hard-wired the signal cable extension into the cab, making it difficult to
reach the implement with the cable end, you may want to purchase an extension cable
from Veris (part #12269). This cable attaches to the signal cable end and allows you to
position the Signal Test Box in close proximity to the coulter-electrodes.


Figure 2.2

Firmly press one lead of the ohmmeter to the #1 coulter blade edge (left hand, standing
behind the unit) and the other lead to the #1 terminal on the test box. Maintain firm
pressure on the ohmmeter lead touching the disk blade. A reading of less than 2 ohms is
normal. Rotate blade ¼ of a turn back and forth as you view the ohmmeter. Any jump in
the readings above 2 ohms indicates a problem.

Figure 2.3

Continue to check each coulter electrode in succession, left to right.
If any coulter electrode exhibits no continuity or resistance higher than 2 ohms, refer to
Procedure #3 Diagnosing EC Signal Problems.

Connect to coulter
blade

Ohmmeter

Connect one lead to Signal Test
Box terminal (corresponding to
each coulter)

Signal extension cable
(from implement)

Advertising
This manual is related to the following products: