Veris Industries TK SERIES Install User Manual

Tk series, Temperature, Installation guide

Advertising
background image

Installation Guide

Temperature

Z205789-0C

Page 1 of 2

©2013 Veris Industries USA 800.354.8556 or +1.503.598.4564 / [email protected] 08131

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.

Other companies’ trademarks are hereby acknowledged to belong to their respective owners.

TM

NOTICE

• This product is not intended for life or safety applications.

• Do not install this product in hazardous or classified locations.

• Read and understand the instructions before installing

this product.

• Turn off all power supplying equipment before working on it.

• The installer is responsible for conformance to all applicable codes.

No responsibility is assumed by Veris Industries for any consequences arising out of the

use of this material.

Product Identification

Product Overview

TK ceiling mounted temperature sensors monitor the temperature of the air in a duct. The design includes a
pre-calibrated sensor housed in a sturdy stainless steel probe with no junction box. The TK has a resistive output
compatible with building control systems. It is warranted to meet accuracy specifications for a period of five years.

TK Series

Temperature Probe

Specifications

Wiring 22 AWG; 2-wire RTD/Thermistor

Housing Stainless Steel

LINITEMP OPTION

Input Power 5-30 VDC

Output 1 µA/°C or 10 mV/°C

Operating Temperature

Range

-25° to 105°C (-13 to 221°F)

Accuracy

Calibration Error

Error over Temperature

1.5°C (35°F) typical; 2.5°C (37°F) max. at 25°C (77°F)
1.8°C (35°F) typical; 3.0°C (34°F) max. over 0° to 70°C (32° to 158°F) range;
2.0°C (35°F) typical; 3.5°C (38°F) max. over -25° to 105°C (-13° to 221°F) range

Increased cable length affects the readings of lower resistance RTDs (100R platinum RTD).

Room temperature error is documented on each unit.

Sensor Type

Probe Length

B = 100R platinum, RTD
C = 1k platinum, RTD
D = 10k T2, Thermistor
E = 2.2k, Thermistor
F = 3k, Thermistor
G = 10k CPC, Thermistor
H = 10k T3, Thermistor
I = 1k Balco (Nickel-iron) RTD
J = 10k Dale, Thermistor
K = 10k w/11k shunt, Thermistor
M = 20k NTC, Thermistor
N = 1800 ohm, Thermistor
P = 10mV/°C, Linitemp
R = 10k US, Thermistor
S = 10k 3A221, Thermistor
T = 100k, Thermistor
U = 20k “D”, Thermistor
CC = 15k, Thermistor

B = 4 1/2" (115 mm)
C = 6” (153 mm)
D = 8" (204 mm)
R = 14” (356 mm)

TK

= Resistive

Cal Certs

0 = None
1 = 1 Point Cal Cert
2 = 2 Point Cal Cert

R0

Output

Advertising