Veris Industries HWS SERIES Install User Manual

Hws series, Notice, Installation guide

Advertising
background image

VERIS INDUSTRIES

environmental SenSorS

inStallation GUiDe

Z204453-0D

PAGE 1

©2010 Veris Industries USA 800.354.8556 or 1.503.598.4564 / [email protected]

06101

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.

Wall Mount with Analog Setpoints, LCD Display,

1% NIST, 2% NIST, 2%, 3%, or 5%

Installer’s Specifications

Power Supply*

15 to 24VDC/24VAC, 100mA max.

Outputs, Analog

Switch Selectable 4-20mA or 0-10V/0-5VDC (switch affects both outputs)

RH Sensor

Digitally profiled thin-film capacitive (32-bit mathematics)

U.S. Patent 5,844,138

Accuracy at 25°C from 10-80% RH**

±2%, 3%, or 5% models

±1% at 20-50% RH (Multi-point calibration NIST traceable)

Reset Rate***

24 hours

Stability

±1% @ 20°C (68°F) annually, for two years

Linearity

Included in Accuracy spec.

Operating Humidity Range

0-100% RH

Temperature Coefficient

±0.1%RH/°C above or below 25°C (typical)

Operating Temperature Range

10° to 35°C (50° to 95°F)

Scaling

0-100% RH

Calibration Offset

Adjustable ±9.9% in 0.1% increments

Setpoint Range

10-80% RH in 1% increments

*One side of transformer secondary is connected to signal common, so an isolation transformer or

dedicated power supply may be required.

**Specified accuracy with 24VDC supplied power with rising humidity.

***Reset Rate is time required to recover to 50% RH after exposure to 90% RH for 24 hours.

To maintain CE compliance the connected power supply must have a CE mark supporting LV + CE

directives.

HWS SerieS

HWS SerieS

Dimensions

NOTICE

• This product is not intended for life or safety applications.

• Do not install this product in hazardous or classified locations.
• Read and understand the instructions before installing
this product.
• Turn off all power supplying equipment before working on it.

• The installer is responsible for conformance to all applicable codes.

ProDuct iDentification

quick install

Select a mounting location away from ventilation sources. The sensor should be

1.

mounted on a vertical wall, about 4 1/2 feet above the floor.

Affix the backplate to the wall.

2.

Wire the device. Refer to wiring diagram.

3.

Install Cover.

4.

1.2"

(29 mm)

3.5"

(89 mm)

4.75"

(121 mm)

-

+

Enter

Setpoint

Accuracy

NIST

= Analog

1 = 1%
2 = 2%
3 = 3%
5 = 5%

HWS

RH Only Device

N = NIST (1 & 2% only)
X = No (2, 3, 5% only)

S

A