External power supply mode – V-Tech IP-MR18 Manual User Manual

Page 7

Advertising
background image

+

+

-

-

+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -

Remove the Jumper

set to Normally Open on the

Unlock Relay mode (default)

JP_LK

1

2

3

Note: Cut off this line when

using external power supply

+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -

Remove the Jumper

set to Normally Closed on the

Unlock Relay mode

+

+

-

-

JP_LK

1

2

3

Note: Cut off this line when

using external power supply

-5-

2. External Power Supply Mode

When the electronic lock is over 12 Vdc, additional power supply for the lock is needed.

• The power supply for the lock must be less than 48Vdc 1.5A.

• The Jumper must be removed when using external power supply. The default setting is

Power-on-to-Unlock type(

Normally open mode

), if use Power-off-to-Unlock type,

change the Unlock Relay mode to

Normally closed mode

.

• If different unlocking time is needed to be configured, change the

Unlock Timing

on

door station.

C. Connection for Power-to-Unlock type:

D. Connection for Power--off-to-Unlock type: