VEGASWING 71A and 75A

11

+

1

2

3

4

+

1

2

3

4

+

+

+

1

2

3

4

+

1

2

3

4

Electrical connection

3.2 Wiring plan

Floating transistor output
(SWING E72 T)

Power supply: 10 … 55 V DC
(for further information see the following con-
nection examples as well as technical data)

To determine the switching status of the tran-
sistor output (mode A/B), the supply cable
(terminals 1 and 4) must be polarised re-
spectively.

Mode A

Max. detection or overfill protection:
- terminal 1: +
- terminal 4: –

Mode B

Min. detection or dry run protection:
- terminal 1: –
- terminal 4: +

Through different connections of the con-
sumer (load), NPN or PNP action can be
preset. Take care that during connection,
terminal 2 has always a more positive voltage
potential than terminal 3.

Connection examples

The transistor switches the supply voltage of
the oscillator to the binary input of a PLC or to
an electrical load.

Mode A

Mode B

U

B

U

B

U

B

U

B

+

1

2

3

4

+

1

2

3

4

U

B

U

B

U

B

U

B

NPN action

PNP action

The transistor switches a second voltage
source with the same reference potential to
the binary input of a PLC or to an electrical
load.

Mode A

NPN action

PNP action

Mode B

NPN action

PNP action

NPN action

PNP action

+

1

2

3

4

+

1

2

3

4

+

+

U

B

U

B

U

B

U

B

U

B

U

B

U

B

U