3 technical data – VEGA VEGABAR 24 User Manual

Page 5

Advertising
background image

VEGABAR 24

5

Product description

1.3 Technical data

Mechanical data

Materials, wetted parts

Process connection

stainless steel 1.4571, PVDF

1)

Diaphragm

ceramic (99,5 % Oxydeceramic)

Seal measuring cell

Viton, Kalrez, EPDM

Materials, non-wetted parts

Housing

high resistance plastic PBT (Polyester)

Earth terminal

stainless steel 1.4305

Indicating module window

glass

Weight

VEGABAR

approx. 0,8 … 8 kg (dependent on process
connection)

Adjustment and indicating elements

Adjustment of the basic functions

2 keys, 1 rotating switch

Menu-guided adjustment with
additional function
- adjustment elements

4 key

- indicating elements

DOT-matrix display, 3 lines with 7 figures each

Indicating module

LC-display with

- bar graph (20 segments)
- digital value (4-digit)
- tendency indicators for raising or lowering

values

Electrical data

Connection

Cable entry

PG 13,5 (for cable-ø 5 … 10 mm)

Screw terminals

for conductor cross-sections of up to

2,5 mm

2

Protective measures

Protection

1)

IP 65

Protection class

III

Overvoltage category

III

CE-conformity

VEGABAR 24 meets the requirements of EMC (89/336/EWG) and NSR (73/23/EWG). The
conformity has been judged acc. to the following standards
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993

1)

Use of a suitable seal for the cable in the PG is necessary for maintaining the housing protection. If the seal
used does not fit the cable, it should be replaced by a suitable one.

Advertising