1 product description, 2 electrical connection, 1 function and configuration – VEGA VEGACONNECT 2 User Manual

Page 2: 1 connection plan 1.2 technical data

Advertising
background image

2

VEGACONNECT

Operating instruction

1 Product description

1.1 Function and configuration

VEGACONNECT 2 is an interface cable
(interface adapter) between communication
capable VEGA-instruments (VEGASON,
VEGAPULS, D-series, VEGABAR,
VEGAMET) and a PC in conjunction with the
adjustment software VEGA Visual Operating.

It is connected via a 9-pole SUB-D socket to
the standard interface of the PC and via
2 mm-plug (2-wire line) to the CONNECT-
sockets of the VEGA-instrument.

Further connection possibilties for the 2-wire
line of VEGACONNECT 2 are:
- the connection line between VBUS-sensor

and signal conditioning instrument

- the 0/4 … 20 mA-signal line of the K

(compact)-versions of the sensors.

VEGACONNECT 2 is located in a rugged
plastic housing and is supplied completely
with connection lines and plug connections.

The voltage supply is made via the RS 232-
interface of the PC.

For operation of VEGACONNECT 2 the
adjustment software VEGA Visual Operating
(VVO) version 2.20 or higher is necessary. It
is installed on the PC under WINDOWS 95
and ensures comfortable configuration and
parameter adjustment of communication
capable VEGA-instruments.

A communication with HART

®-

-protocol is

possible. Hence HART

®-

-capable VEGA-

instruments can be adjusted with the PC and
the software VVO.

2 Electrical connection

2.1 Connection plan

1.2 Technical data

Voltage supply from PC via RS 232
Current consumption max. 8 mA
Voltage

max. 15 V

Transmission rate

9.600 baud

Format 8 bit (ASCII-Code)
Parity

none

Start / Stop

1 bit each

Galvanic isolation

between VBUS

and RS 232

Line lengths

RS 232 approx. 30 cm
VBUS approx. 150 cm

Protection

IP 40

CE-conformity acc. to the following
standards:
EMVG Emission

EN 50081-1 : 1992

Susceptibility EN 50082-2 : 1995

NSR

EN 61010 : 1993

EC-regulations:

73/23 EWG
89/336 EWG

Permissible ambient temperature

-20°C … +60°C

Storage and
transport temperature -20°C … +70°C
Housing material

shock-resistant
Polystyrene
upper part light grey
lower part agate grey

Housing dimensions

W x H x D
= 100 x 52 x 30 mm

Weight
with connection lines

approx. 200 g

VEGACONNECT2

5

4

3

2

1

9

8

7
6

VBUS
2 mm-plug

RS 232
D-Sub-socket
9-pole

RxD
TxD
GND

to sensor

to PC

The two-wire line of VEGACONNECT 2 can be
connected in Ex-area to an Ex-approved
sensor.
VEGACONNECT 2 and PC must not be
located in Ex-area
(see connection example 3).
Classification intrinsic safety:
EEx ia II C / II B
EEx ib II C / II B

Advertising