2 technical data, 1 data – VEGA VEGAWELL 71 User Manual

Page 4

Advertising
background image

4

VEGAWELL 71

2 Technical data

2.1 Data

Power supply

Supply voltage

12 … 36 V DC

Permissible load (dependent on the supply voltage)

Measuring ranges

Measuring range and overload in bar

Measuring range

Overload

0 … 0,1

15

0 … 0,2

20

0 … 0,4

30

0 … 1,0

35

0 … 2,5

50

0 … 5,0

65

0 … 10,0

90

0 … 20,0

130

Output signal

4 … 20 mA-current signal; two-wire technology (supply and measuring signal via a two-
wire line)

Meas. accuracy (relating to the nominal measuring range)

Characteristics

linear

Deviation in characteristics

< 0,5 %

Long term stability of the zero signal

1)

< 0,1 %/2 years

Hysteresis or repeatability

< 0,02 %

Average temperature coefficient of the
zero signal

2)

< 0,20 %/10 K

12

300

600

900

18

24

30

36

Technical data

Supply voltage
in V

1)

Acc. to IEC 770

2)

In the compensated temperature range of 0°C … 80°C; reference temperature 20°C