VEGA D84 Ball valve fitting User Manual

Page 8

Advertising
background image

8

Ball valve fitting

Dismounting

3 Dismounting of pressure transmitter from a filled vessel

Safety instruction:

When dismounting the pressure transmitter, the pressure in the vessel can be max. 2 bar
(200 kPa)

• Remove the electrical connection cables

• Loosen the flange screws of the pressure

transmitter
Safety instruction: Before opening the

flange screws, make sure that the nuts of

the safety pins are mounted. When open-

ing the flange screws the sensor will re-

bound with a force of 250 N over a

distance of 14 cm!
If necessary, pull out the pressure trans-
mitter completely.

• Close the ball valve

(illustrated position: valve closed)

• Open the ventilation valve

• The movement of the pressure

transmitter is limited by the safety
pins.

Advertising