VEGA VEGACAP 65 - transistor (NPN_PNP) User Manual

Page 33

Advertising
background image

33

9 Supplement

VEGACAP 65 • - transistor (NPN/PNP)

30018-EN-130916

Ʋ Colour - Ex-version

Blue

Adjustment elements
Mode switch

Ʋ Min.

Min. detection or dry run protection

Ʋ Max.

Max. detection or overflow protection

DIL switch for measuring range selection

Ʋ range 1

0 … 20 pF

Ʋ range 2

0 … 85 pF

Ʋ range 3

0 … 450 pF

Potentiometer

Switching point adaptation

Voltage supply
Operating voltage

10 … 55 V DC

Power consumption

max. 0.5 W

Electrical protective measures
Protection rating

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium and stainless steel stand-

ard

IP 66/IP 68 (0.2 bar)

4)

Ʋ Aluminium and stainless housing

(optionally available)

IP 66/IP 68 (1 bar)

Overvoltage category

III

Protection class

II

Functional safety (SIL)
Functional safety is already activated on instruments with SIL qualification ex factory. On instru-

ments without SIL qualification ex factory, the functional safety must be activated by the user via

the display and adjustment module or via PACTware for applications according to SIL.

Functional safety according to IEC 61508-4

Ʋ Single channel architecture (1oo1D) up to SIL2

Ʋ double channel diversitary redundant

architecture (1oo2D)

up to SIL3

You can find detailed information in the supplied Safety Manual of the instrument series or under

"www.vega.com", "Downloads", "Approvals".
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully

noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"

and "serial number search" as well as via "Downloads" and "Approvals".

4)

A suitable cable is the prerequisite for maintaining the protection rating.