VEGA VEGAVIB 63 - contactless electronic switch User Manual

Page 12

Advertising
background image

Fig. 3: Inflowing medium

VEGAVIB

63 can be mounted with a lock fitting for height adjustment.

Take note of the pressure information of the lock fitting.

The vibrating element should protrude into the vessel to avoid buildup.
For that reason, avoid using mounting bosses for flanges and screwed
fittings. This applies particularly to use with adhesive products.

In silos for bulk solids, material cones can form and change the
switching point. Please keep this in mind when installing the sensor in
the vessel. We recommend selecting an installation location where the
vibrating rod detects an average value of the material cone.

The vibrating rod must be mounted in a way that takes the
arrangement of the filling and emptying apertures into account.

To compensate measurement errors caused by the material cone in
cylindrical vessels, the sensor must be mounted at a distance of d/6
from the vessel wall.

Lock fitting

Socket

Material cone

12

VEGAVIB

63 • - contactless electronic switch

4 Mounting

29278

-EN

-120418

Advertising